ETHICON ENDO-SURGERY, LLC. ILS 33MM, CURVED; STAPLE, IMPLANTABLE Back to Search Results
Model Number ECS33A
Medical Device Problem Codes Failure to Form Staple (2579); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Failure to Anastomose (1028)
Date of Event 01/06/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Batch # u5dj2a.Additional information was requested and the following was received: what were the indications for surgery? obstructing rectal cancer what surgical procedure was performed? robotic lar did the patient receive any preoperative chemotherapy or radiation? no, but limited prostate radiation in the past what bowel prep did the patient receive prior to surgery? mag citrate, dulcolax and miralax with limited response due to obstruction were there any issues experienced with the device in the initial surgical procedure? no what healthcare professional fired the device and what is his/her experience with the device? lo, np.Highly experienced where in the green gap setting scale was the indicator located prior to firing (low-b, middle-b, or high-b)? between 1/3 and 1/2- pretty snug did the healthcare professional wait 15 seconds after closing the device and then retighten prior to firing? waited 15 seconds without retightening but took about 30 seconds to slowly tighten was the device difficult to close? no was the device difficult to fire? no how many counter-clockwise revolutions of the adjusting knob were used to open the device? 1 and 1/2 did the healthcare professional receive audible & tactile feedback when firing the device? yes was a complete transection of the white breakaway washer visually confirmed? no were there any issues noted with staple formation at any point throughout the care of the patient? if so, please describe the shape and location.Yes.After the failed leak test, they were inspected closely and found to be completely open (right angles/3-sided square) right and left lateral and anterior what is the current status of the patient? received colostomy, discharged device analysis: the product was returned to ethicon endo surgery for evaluation.Visual inspection and functional testing were conducted on the returned device.Visual analysis of the returned sample revealed that the ecs33a device arrived with the anvil missing.Only casing half washer present and there were no staples present.The device was reloaded with staples, a new washer was placed on the device and it was tested for functionality with a test anvil.It fired and formed all the staples as well as completely cut the test media and the breakaway washer without incident.The staple line was complete, and the staples meet the staple form release criteria.As part of ethicon endo surgery¿s quality process, all devices are manufactured, inspected, and released to approved specifications.Although no conclusion could be reached on the cause of the reported event, the instructions for use do contain the following caution: if excessive force is required to close the device, this may indicate there is too much tissue or thickened tissue in the device.Attempting to fire the instrument in this condition may result in poor staple line integrity with possible leakage or disruption.The event described could not be confirmed as no malformed staples were observed and the device performed without any difficulties noted.A manufacturing record evaluation was performed for the finished device batch number, and no non-conformances were identified.
 
Event or Problem Description
It was reported that during a sigmoid colectomy procedure that after completing the firing sequence the stapler seemed to fire as normal and there were two intact donuts.When they went to look in the abdomen there was ¿stool everywhere¿, the staples never grabbed the tissue to do the anastomosis.Surgeon ended up preformed a colostomy on the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ILS 33MM, CURVED
Common Device Name
STAPLE, IMPLANTABLE
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
*  00969
Manufacturer (Section G)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
*   00969
Manufacturer Contact
kara ditty-bovard
475 calle c
guaynabo 
*  
6107428552
MDR Report Key13417377
Report Number3005075853-2022-00610
Device Sequence Number11979559
Product Code GDW
UDI-Device Identifier10705036012412
UDI-Public10705036012412
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K940967
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 02/01/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date07/31/2025
Device Model NumberECS33A
Device Catalogue NumberECS33A
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/25/2022
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/11/2022
Initial Report FDA Received Date02/01/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/12/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-