Model Number MA60AC
Medical Device Problem Codes Device Damaged by Another Device (2915); Material Twisted/Bent (2981)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/20/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A sample device was not returned for analysis.Complaint history and product history records were reviewed and documentation indicated the product met release criteria.Root cause has not been identified.There have been no other complaints reported in the lot number.The manufacturer internal reference number is: (b)(4).
 
Event or Problem Description
A non-healthcare professional (purchaser) reported that, during an intraocular lens (iol) implant procedure, the lens got damaged in cartridge and haptic was bent.Additional information was received from the same reporter that, due to loading error the lens got damaged and the procedure was completed the same day.There was no patient harm associated with the event.The patient was not hospitalized.There was no medical or surgical intervention required as a result of this event.
 
Additional Manufacturer Narrative
The product was not returned.The file indicated the use of a non-qualified cartridge.The company lens is only qualified for use in the cartridges.The file indicated the use of a non-qualified viscoelastic.The handpiece indicated is qualified for this lens when used with a qualified lens/cartridge combination.Information was provided that in the surgeon¿s opinion, the product did not cause or contribute to the event.In the surgeons opinion the event was caused by "loading error".The instructions for use (ifu) instructs that an company qualified delivery system and viscoelastic combination should be used.The use of an unqualified combination may cause damage to the lens and potential complications during the implantation process.Company recommends using the qualified iol delivery system or any other company qualified combination.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACRYSOF MULTIPIECE IOL
Common Device Name
INTRAOCULAR LENS
Manufacturer (Section D)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer (Section G)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key13420458
Report Number1119421-2022-00148
Device Sequence Number17312291
Product Code HQL
UDI-Device Identifier00380652552509
UDI-Public00380652552509
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
P930014
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 04/06/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/28/2022
Device Model NumberMA60AC
Device Catalogue NumberMA60AC.190
Device Lot Number12532103
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/11/2022
Supplement Date Received by Manufacturer03/10/2022
Initial Report FDA Received Date02/02/2022
Supplement Report FDA Received Date04/06/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured03/28/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
DISCOVISC; MONARCH III IOL CARTRIDGE D; MONARCH III IOL INJECTOR
Patient SexMale
-
-