Model Number 400SMTSFT0510
Medical Device Problem Code Difficult or Delayed Separation (4044)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/08/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This device is available for return.A follow up mdr will be submitted upon completion of the device investigation.
 
Event or Problem Description
The patient was undergoing a coil embolization procedure in the internal carotid artery (ica) and the ophthalmic artery using penumbra smart coils (smart coils), a penumbra smart coil detachment handle (handle), and a non-penumbra microcatheter.It should be noted that the patient's anatomy was tortuous.During the procedure, the physician successfully implanted one non-penumbra coil.After advancing a smart coil into the target location, the physician attempted to detach the coil using the handle; however, the smart coil did not detach after two attempts.When approximately two centimeters of the smart coil was retracted back into the microcatheter, the coil unintentionally detached.Next, the physician used the smart coil pusher wire to successfully implant the coil.The handle was also removed.The procedure was completed using non-penumbra coils and the same microcatheter.There was no report of an adverse effect to the patient.
 
Additional Manufacturer Narrative
Evaluation of the returned smart coil confirmed a detached embolization coil.Further evaluation revealed the pet lock was separated, the pull wire was retracted out of the ddt, and the pull tube was stuck inside the returned handle.This damage likely occurred due to the repeated actuation of the handle during the detachment attempts.Further evaluation also revealed the braided shaft was damaged.This damage may have been a result of the reported difficulty detaching during the procedure.The root cause of the difficulty detaching experienced could not be determined.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.Section h.Box 6.Conclusions code 1: 4316 - the investigation findings do not lead to a clear conclusion about the root cause of the reported difficulty detaching during the procedure.H3 other text : placeholder.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PENUMBRA SMART COIL
Common Device Name
HCG, KRD
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
Manufacturer Contact
veronica farris
one penumbra place
alameda, CA 94502
5107483200
MDR Report Key13429280
Report Number3005168196-2022-00037
Device Sequence Number5328724
Product Code HCG
UDI-Device Identifier00814548015101
UDI-Public00814548015101
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K160832
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/04/2022
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/31/2022
Device Model Number400SMTSFT0510
Device Catalogue Number400SMTSFT0510
Device Lot NumberF77432
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Date Report to Manufacturer01/10/2005
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/13/2022
Supplement Date Received by Manufacturer03/17/2022
Initial Report FDA Received Date02/02/2022
Supplement Report FDA Received Date04/04/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/01/2017
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age55 YR
Patient SexFemale
Date Report Sent to FDA01/01/2005
-
-