• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION RUBICON 18; CATHETER, PERCUTANEOUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION RUBICON 18; CATHETER, PERCUTANEOUS Back to Search Results
Model Number 39540
Medical Device Problem Codes Fracture (1260); Difficult to Advance (2920); Material Deformation (2976)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/26/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the catheter fractured.The target lesion was located in the superficial femoral artery (sfa).A 135cm rubicon 18 guide catheter was selected for use.The rubicon guide catheter was advanced approximately 10 cm over a guidewire, and then it became stuck.The proximal shaft was noted to be kinked.A shaft fracture was observed outside of the patient, approximately 40cm from the proximal hub.The catheter was removed still intact.The procedure was completed with another of same device.There were no patient complications.
 
Event or Problem Description
It was reported that the catheter fractured.The target lesion was located in the superficial femoral artery (sfa).A 135cm rubicon 18 guide catheter was selected for use.The rubicon guide catheter was advanced approximately 10 cm over a guidewire, and then it became stuck.The proximal shaft was noted to be kinked.A shaft fracture was observed approximately 40cm proximal from the hub.The procedure was completed with another of same device.No patient complications were reported.
 
Additional Manufacturer Narrative
Device eval by mfr: the rubicon 18 guide catheter was returned and analysis was completed.The device was visually and microscopically inspected for damage.The devices shaft showed damage in the form of a kink located 112.5cm from the tip.A.016 test guidewire was inserted into the catheter lumen and the wire transcended through the device until it reached the kink where a restriction was felt; however, the wire did pass through the device.There was no fracture of the device.Inspection of the remainder of the device revealed no other damage or irregularities.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RUBICON 18
Common Device Name
CATHETER, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key13446374
Report Number2134265-2022-01120
Device Sequence Number4321674
Product Code DQY
UDI-Device Identifier08714729829249
UDI-Public08714729829249
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K122394
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 03/09/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/28/2024
Device Model Number39540
Device Catalogue Number39540
Device Lot Number0028109967
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/10/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 01/26/2022
Supplement Date Received by Manufacturer02/16/2022
Initial Report FDA Received Date02/03/2022
Supplement Report FDA Received Date03/09/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/29/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-