STRYKER NEUROVASCULAR CORK TARGET XL 360 SOFT 6MM X 20CM; DEVICE, NEUROVASCULAR EMBOLIZATION Back to Search Results
Model Number M0036126200
Medical Device Problem Code Premature Separation (4045)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/12/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The device is not available to the manufacturer.
 
Event or Problem Description
It was reported that a coil embolization procedure was performed in internal iliac artery, in a patient.During the procedure the subject coil was pushed and pulled several times inside the lumen of the microcatheter and the subject coil was prematurely detached inside the microcatheter.The detached subject coil was removed out of the patient vascular anatomy and retrieved with a snare device.The procedure was completed and no clinical consequences were reported to the patient due to this event.
 
Additional Manufacturer Narrative
Due to the automated mes system there are controls in the manufacturing process to ensure the product met specifications upon release.Visual inspection: the main coil was returned detached from the coil delivery wire.The coil delivery wire was seen to be kinked.The main coil was seen to be stretched.The main coil was seen to be tangled.The main coil was seen to be kinked/bent.Functional inspection: not required.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.Additional information provided by the customer indicated that the device was confirmed to be in good condition during preparation/prior to use on the patient and was prepared as per the dfu, continuous flush was set up and maintained throughout the clinical procedure.During analysis, the main coil was found to be kinked/bent, tangled and stretched.Based on analysis, it is possible that the coil may have been advanced against friction in the microcatheter during the procedure which in turn could cause damage to the coil and premature detachment when the device was retracted.An assignable cause of procedural factors will be assigned to the as reported (ar) / as analyzed (aa) 'main coil prematurely detached/separated during use' as well as the aa 'main coil stretched', 'main coil tangled' and' main coil kinked/bent' since these issues are associated with a product that met stryker design and manufacturing specifications and was used in accordance with the dfu but due to procedural and/or anatomical factors during use, the product performance was limited.An assignable cause of handling damage will be assigned to the as analyzed 'coil delivery wire kinked/bent' since this issue is due to handling of the product during the clinical procedure.
 
Event or Problem Description
It was reported that a coil embolization procedure was performed in internal iliac artery, in a patient.During the procedure the subject coil was pushed and pulled several times inside the lumen of the microcatheter and the subject coil was prematurely detached inside the microcatheter.The detached subject coil was removed out of the patient vascular anatomy and retrieved with a snare device.The procedure was completed and no clinical consequences were reported to the patient due to this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TARGET XL 360 SOFT 6MM X 20CM
Common Device Name
DEVICE, NEUROVASCULAR EMBOLIZATION
Manufacturer (Section D)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI  NA
Manufacturer (Section G)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI   NA
Manufacturer Contact
tara lopez
47900 bayside parkway
fremont, CA 94538
5104132500
MDR Report Key13472300
Report Number3008881809-2022-00050
Device Sequence Number17350116
Product Code HCG
UDI-Device Identifier07613327004625
UDI-Public07613327004625
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K153658
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/27/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/03/2024
Device Model NumberM0036126200
Device Catalogue NumberM0036126200
Device Lot Number22841350
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/13/2022
Supplement Date Received by Manufacturer04/26/2022
Initial Report FDA Received Date02/07/2022
Supplement Report FDA Received Date04/27/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/05/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
UNKNOWN MICROCATHETER; UNKNOWN SNARE DEVICE
Outcome Attributed to Adverse Event Required Intervention; Other;
Patient SexUnknown
-
-