MAUDE Adverse Event Report: THORATEC CORPORATION HEARTMATE 3 SEALED OUTFLOW GRAFT WITH BEND RELIEF; VENTRICULAR (ASSISST) BYPASS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

THORATEC CORPORATION HEARTMATE 3 SEALED OUTFLOW GRAFT WITH BEND RELIEF; VENTRICULAR (ASSISST) BYPASS Back to Search Results
Model Number 105581US
Medical Device Problem Code No Apparent Adverse Event (3189)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/13/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Manufactures investigation conclusion: evaluation of the returned outflow graft assembly, lot number 7683225, confirmed the reported flecks in the lumen of the outflow graft.The sealed outflow graft and outflow graft bend relief were returned in like-new condition.Both the outflow graft and outflow graft bend relief were free of distortion.Examination of the interior surface of the sealed outflow graft revealed 2 flecks both situated approximately 2.5 inches from the outflow graft hardware.The flecks were removable with tweezers.The debris appeared to be a piece of the pre-clot gelatin.The interior surfaces of the sealed outflow graft and graft attachment were otherwise unremarkable.The bend relief material was unremarkable.The screw ring revealed no evidence of damage or defects to the screw threads.The outflow ptfe washer was present and properly seated within the screw ring.The graft attachment o-ring and c-ring were both free of damage and located in the correct grooves within the graft attachment.Outflow graft, lot number 7683225, was shipped to the supplier for further analysis.Per the supplier¿s investigation, the excess gelatin particulate was likely introduced to the graft after the impregnation process, as the supplier¿s final inspection did not identify gelatin specs prior to release.The cause of the gelatin particles being present could not be conclusively determined at this time.Additionally, abbott performed a voluntary review of internal procedures.The relevant manufacturing and inspection procedures will be updated to include inspection for excess gelatin specks.Abbott will continue to monitor this issue.The heartmate 3 lvas ifu, rev.C is currently available.The ifu outlines the steps for preparing a heartmate 3 sealed outflow graft for implantation, including ¿inspect the interior of the graft and remove any debris¿.The ifu also warns that a complete backup system must be available on-site and in close proximity for use in an emergency.The relevant sections of the device history records for the outflow graft assembly, lot number 7683225 were reviewed and showed no deviations from manufacturing or quality assurance specifications.No further information was provided.The manufacturer is closing the file on this event.
 
Event or Problem Description
It was reported that during pump preparation the implanting surgeon noticed a small fleck in the outflow graft.The site decided not to use it as it was reported as ¿out of box failure.¿.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HEARTMATE 3 SEALED OUTFLOW GRAFT WITH BEND RELIEF
Common Device Name
VENTRICULAR (ASSISST) BYPASS
Manufacturer (Section D)
THORATEC CORPORATION
6035 stoneridge drive
pleasanton CA 94588
Manufacturer (Section G)
THORATEC CORPORATION
6035 stoneridge drive
pleasanton CA 94588
Manufacturer Contact
bob fryc
6035 stoneridge drive
pleasanton, CA 94588
7818528204
MDR Report Key13497814
Report Number2916596-2022-00836
Device Sequence Number11790539
Product Code DSQ
UDI-Device Identifier00813024013266
UDI-Public00813024013266
Combination Product (Y/N)N
Initial Reporter StateMN
Initial Reporter CountryUS
PMA/510(K) Number
P160054
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 02/09/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/13/2023
Device Model Number105581US
Device Catalogue Number105581US
Device Lot Number7683225
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/23/2021
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/08/2022
Initial Report FDA Received Date02/09/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/13/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-