MAUDE Adverse Event Report: ALCON LABORATORIES IRELAND LTD. ACRYSOF IQ ASPHERIC IOL WITH THE ULTRASERT PRE-LOADED DELIVERY SYSTEM; INTRAOCULAR LENS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALCON LABORATORIES IRELAND LTD. ACRYSOF IQ ASPHERIC IOL WITH THE ULTRASERT PRE-LOADED DELIVERY SYSTEM; INTRAOCULAR LENS Back to Search Results
Model Number AU00T0
Medical Device Problem Codes Defective Component (2292); Failure to Eject (4010)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/17/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A sample device was not returned for analysis.Complaint history and product history records were reviewed and documentation indicated the product met release criteria.Root cause has not been identified.There have been no other complaints reported in the lot number.The manufacturer internal reference number is: (b)(4).
 
Event or Problem Description
A nurse reported that during an intraocular lens (iol) implantation procedure, there was challenges with the plunger but surgeon decided to use the device anyway.The device was prepared normally according to instructions and pushed plunger forward and noticed that plunger was sliding on top of the lens.The technician pulled the plunger back and asked the surgeon to check the lens.The surgeon inspected the lens and said the lens could still be used.The surgeon pushed plunger forward and this time plunger pushed the lens forward as it should.The lens was placed in the eye but the trailing haptic of the lens was not properly folded inside the lens but was stuck between the plunger and the tip of the delivery system.Lens was freed from the delivery system with forceps.The lens remained undamaged and the lens was fitted to the eye.The surgeon had used forceps was used to remove the haptic from between the injector tip and plunger.The lens remained undamaged and the lens was fitted to the eye using an auxiliary instrument.The is no patient harm was reported.No further information available.
 
Additional Manufacturer Narrative
A sample device was not returned for analysis.Complaint history and product history records were reviewed and documentation indicated the product met release criteria.Root cause has not been identified.There have been no other complaints reported in the lot number.The manufacturer internal reference number is: (b)(4).
 
Event or Problem Description
A nurse reported that during an intraocular lens (iol) implantation procedure, there was challenges with the plunger but surgeon decided to use the device anyway.The device was prepared normally according to instructions and pushed plunger forward and noticed that plunger was sliding on top of the lens.The technician pulled the plunger back and asked the surgeon to check the lens.The surgeon inspected the lens and said the lens could still be used.The surgeon pushed plunger forward and this time plunger pushed the lens forward as it should.The lens was placed in the eye but the trailing haptic of the lens was not properly folded inside the lens but was stuck between the plunger and the tip of the delivery system.Lens was freed from the delivery system with forceps.The lens remained undamaged and the lens was fitted to the eye.The surgeon had used forceps was used to remove the haptic from between the injector tip and plunger.The lens remained undamaged and the lens was fitted to the eye using an auxiliary instrument.The is no patient harm was reported.No further information available.
 
Additional Manufacturer Narrative
We are unable to determine the root cause for the reported complaint "plunger override.".Sample was not returned for evaluation.Plunger override may occur: if the lens has become misaligned in the lens bay during the manufacturing process.Due to the use of a non-qualified viscoelastic.Material properties of non-qualified ovds may contribute to underfill, overfill, misfolding of the haptics, or other inconsistent folding outcomes.If inadequate viscoelastic is placed in the device this will cause inadequate coverage of the lens fold path which may cause the lens to advance incorrectly or become ¿stuck¿ in the device allowing the plunger to override the lens.If the operating room temperature is too high 23°c / 73° f lens folding consistency is negatively affected, the lens is more adherent and this may inhibit lens advancement.Any of the above listed causes alone, or in combination, may create the reported event.The reported trailing haptic issues cannot be confirmed, however they most likely occurred due to re-use of the lens post plunger override observation.Ifu (instructions for use) does not instruct to re-use the device.In addition to this, the ifu instructs: "visually inspect the lens to determine the position of the leading and trailing haptics.Verify that the plunger is in contact with the trailing optic edge." based on the results from the product history record, the products met release criteria.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACRYSOF IQ ASPHERIC IOL WITH THE ULTRASERT PRE-LOADED DELIVERY SYSTEM
Common Device Name
INTRAOCULAR LENS
Manufacturer (Section D)
ALCON LABORATORIES IRELAND LTD.
cork business&technology park
model farm road
cork 00000
EI  00000
Manufacturer (Section G)
ALCON LABORATORIES IRELAND LTD.
cork business&technology park
model farm road
cork 00000
EI   00000
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key13504369
Report Number9612169-2022-00055
Device Sequence Number14778174
Product Code HQL
UDI-Device Identifier00380652394734
UDI-Public00380652394734
Combination Product (Y/N)N
Initial Reporter CountryFI
PMA/510(K) Number
P930014
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 05/09/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/04/2024
Device Model NumberAU00T0
Device Lot Number25138732
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/26/2022
Supplement Date Received by Manufacturer04/19/2022
Initial Report FDA Received Date02/10/2022
Supplement Report FDA Received Date05/09/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured02/04/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
AUXILIARY INSTRUMENT; FORCEPS; UNSPECIFIED DISCOVISC
Patient SexUnknown
-
-