As reported, during an hemodialysis (hd) catheter placement, a micropuncture transitionless access set was being used, and it uncoiled while inside of the patient.The hd catheter was being placed, and the wire met resistance.The physician attempted to retract the wire, but it uncoiled in the patient.The wire was pulled out and no wire was retained.An x-ray was used to confirm.No adverse effects to the patient have been reported due to this occurrence.Additional patient and event information has been requested.
|
|
Event summary: as reported, during an hemodialysis (hd) catheter placement, a micropuncture transitionless access set uncoiled while inside of the patient.The hd catheter was being placed, and the wire met resistance.The physician attempted to retract the wire, but it uncoiled in the patient.The wire was pulled out and no wire was retained.An x-ray was used to confirm.No adverse effects to the patient have been reported due to this occurrence.Investigation - evaluation: reviews of the complaint history, device history record, instructions for use, and quality control procedures and a visual inspection of the device were conducted during the investigation.One used wire guide from the mpis-501-sst set was returned to cook for investigation.The wire was unraveled and elongated at approximately 38.5cm from the proximal end.A document-based investigation evaluation was performed.Relevant nonconformances were recorded for wire guide component lots associated with this product lot; all devices were scrapped and not replaced.There are 100% inspections to capture this nonconformance.There have been no other reported complaints for this lot number.The device history record review provides objective evidence that the device was manufactured to specification.There is no evidence of nonconforming devices from the complaint lot in house or in the field.A review of relevant manufacturing documents was conducted.It was concluded that the device aspect in question was functionally inspected by quality control and no notable gaps in production or processing controls were noted.There is no indication that a design or process related failure mode contributed to the reported event.Sufficient inspection activities are in place to identify this failure mode prior to distribution.The device is provided with instructions for use which caution, ¿do not attempt to insert or withdraw the wire guide and/or introducer if resistance is felt,¿ and, ¿withdrawal or manipulation of the distal spring coil portion of the mandril wire guide through a needle tip may result in breakage.¿ based on the available information, cook has concluded that a component failure unrelated to manufacturing or design deficiencies contributed to this incident.Cook will continue monitoring of similar complaints and has notified the appropriate personnel of this event.Per the quality engineering risk assessment, no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|