BARD PERIPHERAL VASCULAR, INC. ULTRAVERSE RX; PTA BALLOON DILATATION CATHETER Back to Search Results
Model Number U4150230RX
Medical Device Problem Codes Failure to Advance (2524); Material Deformation (2976)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/14/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this product and lot.Investigation summary: one ultraverse rx pta dilatation catheter was returned for evaluation.No kinks noted to the catheter shaft; no other anomalies noted on the inflation luer.Under microscopic observation it was observed that the inner guide wire lumen was kinked at the proximal end of the balloon.No functional testing was performed due to the condition of the device.Therefore, the investigation for the reported unable to cross lesion remains inconclusive as the conditions of use could not be replicated in laboratory conditions.However, the investigation was confirmed for material deformation as the inner guide wire lumen was noted to be kinked and was observed during the microscopic observation.A definitive root cause for the reported unable to cross lesion and kink could not be determined based upon the provided information.Labeling review: a review of product labeling documentation (e.G., procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.(expiry date: 10/2023).
 
Event or Problem Description
It was reported that during an angioplasty procedure of a highly calcified target lesion below the knee, the pta balloon was allegedly unable to cross the lesion.It was further reported that the catheter shaft was allegedly kinked.The procedure was completed using another device.There was no reported patient injury.
 
Additional Manufacturer Narrative
Manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this product and lot.Investigation summary: one ultraverse rx pta dilatation catheter was returned for evaluation.No kinks noted to the catheter shaft; no other anomalies noted on the inflation luer.Under microscopic observation it was observed that the inner guide wire lumen was kinked at the proximal end of the balloon.No functional testing was performed due to the condition of the device.Therefore, the investigation for the reported unable to cross lesion remains inconclusive as the conditions of use could not be replicated in laboratory conditions.However, the investigation was confirmed for material deformation as the inner guide wire lumen was noted to be kinked and was observed during the microscopic observation.A definitive root cause for the reported unable to cross lesion and kink could not be determined based upon the provided information.Labeling review: a review of product labeling documentation (e.G., procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.(expiry date: 10/2023).
 
Event or Problem Description
It was reported that during an angioplasty procedure of a highly calcified target lesion below the knee, the pta balloon was allegedly unable to cross the lesion.It was further reported that the catheter shaft was allegedly kinked.The procedure was completed using another device.There was no reported patient injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRAVERSE RX
Common Device Name
PTA BALLOON DILATATION CATHETER
Manufacturer (Section D)
BARD PERIPHERAL VASCULAR, INC.
1625 w 3rd st.
tempe AZ 85281
Manufacturer (Section G)
CLEARSTREAM TECHNOLOGIES LTD.
moyne upper
enniscorthy, co. wexford N A
EI   N A
Manufacturer Contact
judy ludwig
800 w. rio salado pkwy
tempe, AZ 85281
4803032689
MDR Report Key13511945
Report Number2020394-2022-00094
Device Sequence Number17470946
Product Code LIT
UDI-Device Identifier00801741056383
UDI-Public(01)00801741056383
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K131199
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 02/11/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberU4150230RX
Device Catalogue NumberU4150230RX
Device Lot NumberCMEY0594
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/28/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/14/2022
Initial Report FDA Received Date02/11/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age80 YR
Patient SexFemale
Patient Weight40 KG
-
-