| Model Number |
N/A |
| Medical Device Problem Codes |
Fluid/Blood Leak (1250); Material Deformation (2976)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/12/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The device has not been returned to the manufacturer for evaluation.A lot history review (lhr) of refw4392 showed 13 other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
It was reported the picc line leaked at the purple hub.It was stated the hub did not appear cracked or leaking at the end where the injection cap screw on.The leaking can be visualized from the body of the purple lumen.This occurred during the first 24 hours of having the picc in place.Add info rcvd 02/02/2022: placement info: placed on (b)(6) exchanged on (b)(6).What type of catheter securement was utilized: 3m securement device.Was there patient harm reported?: no, except patient had to undergo a second procedure (picc exchange).
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, trend analysis, applicable previous investigation(s), sample (if available), and applicable fmea documents.Based on a review of this information, the following was concluded: the complaint of a leaking catheter was confirmed and the cause was manufacturing-related.The product returned for evaluation was one 5fr d/l powerpicc catheter.Light usage residues were observed.An attempt to infuse water through the sample using a 12ml syringe revealed both lumens to be patent to infusion; however, during pressurization, leakage was observed at the junction between the purple luer adapter and the syringe.Inspection of the purple luer adapter using an iso taper gauge revealed that the gauge could not be fully inserted into the luer orifice.Microscopic inspection of the purple luer adapter revealed a protrusion in the luer material within the orifice.The mold defect appeared to prevent firm attachment of the syringe, as well as full insertion of the taper gauge.The molding defect observed within the luer orifice prevented firm attachment with the syringe and resulted in leakage at the interface between the catheter and the syringe.Photographs of the sample have been forwarded to the manufacturing site for further evaluation.H3 other text : evaluation findings are in section h.11.
|
| |
|
Event or Problem Description
|
|
It was reported the picc line leaked at the purple hub.It was stated the hub did not appear cracked or leaking at the end where the injection cap screw on.The leaking can be visualized from the body of the purple lumen.This occurred during the first 24 hours of having the picc in place.Add info rcvd 02/02/2022: placement info: placed on 1/12 exchanged on 1/15.What type of catheter securement was utilized: 3m securement device.Was there patient harm reported?: no, except patient had to undergo a second procedure (picc exchange).
|
| |
|
Search Alerts/Recalls
|