As reported, during an angioplasty procedure and using a advance 14 lp low profile balloon catheter, the balloon quickly lost pressure due to a pinhole in the balloon material.An inflation device was used.And the inflation pressure did not make it past 6atm.Inflation failed during the first attempt.A 5fr cook sheath of unknown length was also utilized during the procedure.Patient's anatomy was not noted to be tortuous or calcified.The lesion was located in the posterior tibial artery.The balloon was removed through the sheath.The procedure was successfully completed with another device of the same type.No unintended section of the device remained inside of the patient's body.No additional procedures were required due to the occurrence.No adverse effects were reported due to the occurrence.
|
|
As reported, during an angioplasty procedure and using a advance 14 lp low profile balloon catheter, the balloon quickly lost pressure due to a pinhole in the balloon material.An inflation device was used.And the inflation pressure did not make it past 6atm.Inflation failed during the first attempt.A 5fr cook sheath of unknown length was also utilized during the procedure.Patient's anatomy was not noted to be tortuous or calcified.The lesion was located in the posterior tibial artery.The balloon was removed through the sheath.The procedure was successfully completed with another device of the same type.No unintended section of the device remained inside of the patient's body.No additional procedures were required due to the occurrence.No adverse effects were reported due to the occurrence.
|
|
Blank fields on this form indicate the information is unknown, unchanged, or unavailable.Summary of event: as reported, during an angioplasty procedure and using a advance 14 lp low profile balloon catheter, the balloon quickly lost pressure due to a pinhole in the balloon material.An inflation device was used.And the inflation pressure did not make it past 6atm.Inflation failed during the first attempt.A 5fr cook sheath of unknown length was also utilized during the procedure.Patient's anatomy was not noted to be tortuous or calcified.The lesion was located in the posterior tibial artery.The balloon was removed through the sheath.The procedure was successfully completed with another device of the same type.No unintended section of the device remained inside of the patient's body.No additional procedures were required due to the occurrence.No adverse effects were reported due to the occurrence.Investigation evaluation: reviews of the complaint history, device history record, drawings, instructions for use (ifu), quality control procedures, and specifications were conducted during the investigation.A visual inspection of the returned complaint device was also conducted.The complaint device was returned to cook for investigation.A physical examination and leak test of the returned device confirmed that the balloon leaked from near the proximal bond, but not from the bond itself.Cook completed a review of the device history record (dhr).The dhr for the reported lot found no related non-conformances.A related subassembly lot found 2 relevant non-conformances; all non-conforming products were scrapped, and the lot is inspected 100%.A review of complaint history records shows no other related complaints associated with the complaint device lot.Cook determined that no nonconforming product exists in house or in the field.Cook reviewed the device master record (dmr) and product labeling, including the ifu, to confirm adequate manufacturing specifications, operation parameters, and the design verification testing of the device are in place to identify and prevent this failure mode prior to distribution.The instructions for use (ifu) provides the following information to the user related to the reported failure mode: warnings do not exceed rated burst pressure.Rupture of balloon may occur.Rupture of balloon may occur.Adhere to balloon inflation pressure parameters in the compliance card insert.Over-inflation may cause rupture of the balloon, with resultant damage to the vessel wall.Use of a pressure gauge is recommended to monitor inflation pressures.Do not use a power injector for balloon inflation.Rupture may occur.Balloon introduction and inflation if balloon pressure is lost and / or balloon rupture occurs, deflate balloon and remove balloon and sheath as a unit.Balloon deflation and withdrawal if resistance is encountered during withdrawal, apply negative pressure with a larger syringe before proceeding.If resistance continues, remove balloon and sheath as a unit.How supplied upon removal from package, inspect the product to ensure no damage has occurred.Cook concluded that a component failure unrelated to the design or manufacture of the compliant device caused this incident.The appropriate personnel have been notified and cook will continue to monitor for similar events.Per the quality engineering risk assessment, no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|