| Catalog Number |
0010211 |
| Medical Device Problem Codes |
Defective Device (2588); Patient-Device Incompatibility (2682); Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Codes |
Abscess (1690); Adhesion(s) (1695); Unspecified Infection (1930); Hernia (2240); Insufficient Information (4580)
|
| Date of Event |
03/17/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol ventrio patch on (b)(6) 2016.As reported, the patient is making a claim for an adverse patient outcome against the ventrio patch.Attorney alleges that the patient had subsequent surgical intervention due to the hernia mesh device.It is also alleged that the patient experienced emotional distress and the device was defective.
|
| |
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Should additional information be provided, a supplemental emdr will be submitted.
|
| |
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Addendum: h11: this supplemental emdr is submitted to document additional information provided and to correct the patient id and gender.Root cause is inconclusive, no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-sep-2014) is considered to be a best estimate.This supplemental emdr represents the bard/davol ventrio mesh (device #2).An additional supplemental emdr was submitted to represent the bard flat mesh (device #1).Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol ventrio patch on (b)(6) 2016.As reported, the patient is making a claim for an adverse patient outcome against the ventrio patch.Attorney alleges that the patient had subsequent surgical intervention due to the hernia mesh device.It is also alleged that the patient experienced emotional distress and the device was defective.Addendum per additional information provided: (b)(6) 2013 - patient was diagnosed with recurrent abdominal wall hernia thereby underwent open repair with the implant of bard flat mesh (device #1).Per op notes, "a bard flat mesh (device #1) was placed and sutured." (b)(6) 2016 - patient was diagnosed with recurrent abdominal wall hernia thereby underwent repair with the implant of ventrio mesh (device #2).(note: no implant op notes were provided for this procedure.) (b)(6) 2017 - patient was diagnosed with infection, recurrent ventral hernia thereby underwent open repair with the removal of mesh (device #1 & #2).Per op notes, "a large abscess cavity as found on the top of the mesh (device #1 & #2).The mesh (device #1 & #2) was removed.".
|
| |
|