| Model Number |
75023710 |
| Medical Device Problem Codes |
Break (1069); Deformation Due to Compressive Stress (2889)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/28/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Internal complaint reference: (b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that, during a thr surgery, the polarstem ball head impactor broke.No pieces fell into patient.Surgery was resumed, without any delay, with a smith and nephew back-up device.Patient was not harmed, or further consequences were reported.
|
| |
|
Additional Manufacturer Narrative
|
|
H3, h6: it was reported that, during a thr surgery, the polarstem ball head impactor and polarstem modular head for 21000662 broke.No pieces fell into patient.Surgery was resumed, without any delay, with a smith and nephew back-up device.Patient was not harmed, or further consequences were reported.The device in scope of this complaint, was not returned for investigation.A review of the complaint history was performed.The occurrence of the reported failure mode is within its expected risk level as per risk management.A review of the risk management documentation verified the failure mode and severity of the reported issue.Due to insufficient information it is not possible to perform a review of past corrective actions.There are no indications that the complaint device did not meet manufacturing specifications upon release for distribution.Based on available information, the reported failure mode could not be confirmed.A relationship between the reported event and the device cannot be confirmed.Due to insufficient information, it is not possible to speculate about factors which could have contributed to the reported event.No probable cause can be determined.The need for corrective action is not indicated.Nevertheless, smith + nephew will continue to monitor this device for similar issues.Should additional information become available, this complaint will be reopened.Internal complaint reference: (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
H3, h6: it was reported that, during a thr surgery, the polarstem ball head impactor and polarstem modular head for 21000662 broke.No pieces fell into patient.Surgery was resumed, without any delay, with a smith and nephew back-up device.Patient was not harmed, or further consequences were reported.The device in scope of this complaint, was returned for investigation.The reported failure mode was confirmed upon visual inspection.A review of the complaint history was performed and no further complaints were found for the affected lot number.A review of the batch record revealed no deviations from the standard manufacturing process.A review of the risk management documentation verified the failure mode and severity of the reported issue.No prior escalation actions are related to the reported issue.Based on the performed investigations, the reported failure mode could be confirmed.A relationship between the reported event and the device can be confirmed.The reported device met manufacturing specifications upon release for distribution.No probable cause can be determined.Normal wear and tear through repeated use is known to contribute to the reported event.According to document "processing (cleaning, disinfection and sterilization) of instruments from smith & nephew orthopaedics ag" (lit.N°03389-en 1363 v3 11/19), all devices must be inspected and controlled for proper functioning after cleaning/disinfection.The need for corrective action is not indicated.Nevertheless, smith + nephew will continue to monitor this device for similar issues.This investigation is considered closed.The complaint device will be discarded.
|
| |
|
Event or Problem Description
|
|
It was reported that, during a thr surgery, the polarstem ball head impactor tip is deformed.No pieces fell into patient.Surgery was resumed, without any delay, with a smith and nephew back-up device.Patient was not harmed, or further consequences were reported.
|
| |
|