MAUDE Adverse Event Report: C.R. BARD, INC. (BASD) -3006260740 EZ HUBER 20G X 25MM; SET, ADMINISTRATION, INTRAVASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (BASD) -3006260740 EZ HUBER 20G X 25MM; SET, ADMINISTRATION, INTRAVASCULAR Back to Search Results
Model Number N/A
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/27/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported blood withdrawal via port, after the blood withdrawal was finished and the tube was flushed and blocked with positive pressure, a drop of blood was hanging at the transition from tube to needle.
 
Additional Manufacturer Narrative
The date of event was not provided by the complainant/reporter, the date reflected in this report is the date bd became aware of the event.The device has not been returned to the manufacturer for evaluation.A lot history review (lhr) of refz3339 showed no other similar product complaint(s) from this lot number.Device not returned for evaluation.
 
Additional Manufacturer Narrative
The date of event was not provided by the complainant/reporter, the date reflected in this report is the date bd became aware of the event.The device has not been returned to the manufacturer for evaluation.A lot history review (lhr) of refz3339 showed no other similar product complaint(s) from this lot number.Device not returned for evaluation.
 
Event or Problem Description
It was reported blood withdrawal via port, after the blood withdrawal was finished and the tube was flushed and blocked with positive pressure, a drop of blood was hanging at the transition from tube to needle.
 
Additional Manufacturer Narrative
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.A lot history review (lhr) of reez3339 showed no other similar product complaint(s) from this lot number.
 
Event or Problem Description
It was reported blood withdrawal via port, after the blood withdrawal was finished and the tube was flushed and blocked with positive pressure, a drop of blood was hanging at the transition from tube to needle.
 
Event or Problem Description
It was reported blood withdrawal via port, after the blood withdrawal was finished and the tube was flushed and blocked with positive pressure, a drop of blood was hanging at the transition from tube to needle.
 
Additional Manufacturer Narrative
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, applicable previous investigation(s), sample analysis, applicable fmea documents, and applicable manufacturing records.Based on a review of this information, the following was concluded: the complaint of a leak in the infusion set was confirmed and the cause appeared to be associated with the manufacturing process.One ez huber infusion set was returned for investigation.The sample exhibited evidence of use.A functional test revealed fluid leaking from the interface between the extension set tubing and the needle housing.A microscopic examination of the leak site revealed variation in the adhesive bond between the extension set tubing and the needle housing.The leak appears to be associated with the breach in the adhesive bond between the tubing and the needle housing.Bd is working closely with manufacturing to prevent recurrence of the reported event.H3 other text : evaluation findings are in section h.11.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EZ HUBER 20G X 25MM
Common Device Name
SET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
C.R. BARD, INC. (BASD) -3006260740
605 north 5600 west
salt lake city 84116
Manufacturer (Section G)
BARD REYNOSA S.A. DE C.V. -9617592
blvd. montebello #1
parque industrial colonial
reynosa, tamaulipas 88780
MX   88780
Manufacturer Contact
kelsey erickson
605 north 5600 west
salt lake city 84116
8015950700
MDR Report Key13544290
Report Number3006260740-2022-00345
Device Sequence Number12066049
Product Code FPA
UDI-Device Identifier00801741089169
UDI-Public(01)00801741089169
Combination Product (Y/N)N
Initial Reporter CountrySZ
PMA/510(K) Number
K071846
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Distributor
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 04/19/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue NumberSHG20-100
Device Lot NumberREEZ3339
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 01/27/2022
Supplement Date Received by Manufacturer03/02/2022
04/19/2022
Initial Report FDA Received Date02/16/2022
Supplement Report FDA Received Date03/03/2022
04/21/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured12/01/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-