| Model Number |
1637G |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/01/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that a patient underwent an unknown procedure in (b)(6) of 2022 and suture was used.During the procedure, it was noted that the item is defective, sutures keep breaking.There were no patient consequences reported.Additional information was requested.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint number: (b)(4).If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.A manufacturing record evaluation was performed for the finished device lot, and no non-conformances were identified.Additional information was requested, and the following was obtained: what was the initial procedure? what is the procedure & event date? could you please confirm if the issue occurred before used the device in the patient of while suturing? please confirm.What was used to complete the procedure? could you please clarify if the patient suffer from any consequence due to the issue? if yes please provide more details.How many devices present the issue? please confirm.Could you please confirm if rlmhud is the correct lot number? if not please provide.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Date sent to the fda: 02/16/2022.The following information was requested, but was unavailable: the only information i received is they keep breaking.All 3 boxes are lot rlmhud.This was shipped to you (b)(6) 2022.What was the initial procedure? what is the procedure & event date? could you please confirm if the issue occurred before used the device in the patient of while suturing? please confirm what was used to complete the procedure? could you please clarify if the patient suffer from any consequence due to the issue? if yes please provide more details.How many devices present the issue? please confirm.Could you please confirm if rlmhud is the correct lot number? if not please provide.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Date sent to the fda: 3/15/2022.H6 component code: g07002 no device problem found.H3 investigational summary: two sealed boxes ((b)(4) ea) and an opened box with eight packets of product code 1637 were returned to ethicon inc for analysis with the packaging closed.Upon initial inspection to the samples no external damages were observed on the packets.In order to evaluate the conditions of the returned samples, thirteen packets were opened, and no defects were detected.The swage and attachment area were noted to be as expected.The sutures were dispensed without problems and examined along of the strand to detect any issue related to damaged or breakage suture and no defects were observed during evaluation.Functional test was performed, and the tensile strength results were above the minimum requirements.As part of our quality process, the manufacturing records of this lot-serial number were reviewed, and the manufacturing standards were met prior to the release of this batch.As part of ethicon quality process, all devices are manufactured, inspected, and released to approved specifications.Additional complaint information monitoring for potential safety signals is conducted through complaint trending as part of post-market surveillance.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|