| Model Number |
G49933 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/09/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Name and address: phone: (b)(6).This report includes information known at this time.A follow up report will be submitted should additional relevant information become available.
|
| |
|
Event or Problem Description
|
|
As reported, during a retrograde intrarenal surgery a universa soft ureteral stent was used.They physician wanted to insert the device into the patient's ureteral.When the or nurse opened the device package they noticed that one side of the pigtail loop was ruptured.The physician used another new same type device to complete the procedure without difficulty.No unintended section of the device remained inside of the patient's body.No additional procedures were required due to the occurrence.No adverse effects were reported due to the occurrence.
|
| |
|
Additional Manufacturer Narrative
|
|
Name and address: phone: (b)(6).This report includes information known at this time.A follow up report will be submitted should additional relevant information become available.
|
| |
|
Event or Problem Description
|
|
As reported, during a retrograde intrarenal surgery a universa soft ureteral stent was used.They physician wanted to insert the device into the patient's ureteral.When the or nurse opened the device package they noticed that one side of the pigtail loop was ruptured.The physician used another new same type device to complete the procedure without difficulty.No unintended section of the device remained inside of the patient's body.No additional procedures were required due to the occurrence.No adverse effects were reported due to the occurrence.
|
| |
|
Event or Problem Description
|
|
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
|
| |
|
Additional Manufacturer Narrative
|
|
Blank fields on this form indicate the information is unknown, unavailable, or unchanged.Event summary as reported, during a retrograde intrarenal surgery a universa soft ureteral stent was used.They physician wanted to insert the device into the patient's ureteral.When the or nurse opened the device package they noticed that one side of the pigtail loop was ruptured.The physician used another new same type device to complete the procedure without difficulty.No unintended section of the device remained inside of the patient's body.No additional procedures were required due to the occurrence.No adverse effects were reported due to the occurrence.Investigation - evaluation reviews of the complaint history, device history record, instructions for use, specifications, and quality control procedures and a visual inspection of the device were conducted during the investigation.The device was returned for investigation.The coil on the stent¿s tethered end was observed to be separated.The separated end was still threaded on the tether.A document-based investigation evaluation was performed.No related non-conformances were recorded, and there have been no other reported complaints for this lot number.The device history record review provides objective evidence that the device was manufactured to specification.There is no evidence of nonconforming devices from the complaint lot in house or in the field.A review of relevant manufacturing documents was conducted.There is no indication that a design or process related failure mode contributed to the reported event.Sufficient inspection activities are in place to identify this failure mode prior to distribution.The device is provided with instructions for use which state, ¿upon removal from package, inspect the product to ensure no damage has occurred.¿ based on the available information, cook has concluded that a cause for the stent separation could not be determined.Cook will continue monitoring of similar complaints and has notified the appropriate personnel of this event.Per the quality engineering risk assessment, no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
| |
|
Search Alerts/Recalls
|