MAUDE Adverse Event Report: STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON PKR BASEPLATE #5 LM/RL; PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON PKR BASEPLATE #5 LM/RL; PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER Back to Search Results
Model Number 5620-B-501
Medical Device Problem Code Loss of Osseointegration (2408)
Health Effect - Clinical Code Inadequate Osseointegration (2646)
Date of Event 12/15/2021
Type of Reportable Event Serious Injury
Event or Problem Description
The patient received a removal of the sled prosthesis due to aseptic loosening on (b)(6) 2021.During removal of the sled prosthesis, it was noticed that the femoral part was broken.
 
Additional Manufacturer Narrative
It was noted that the device is not available for evaluation.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.
 
Additional Manufacturer Narrative
It was noted that the device is not available for evaluation.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.
 
Event or Problem Description
The patient received a removal of the sled prosthesis due to aseptic loosening on (b)(6) 2021.During removal of the sled prosthesis, it was noticed that the femoral part was broken.
 
Additional Manufacturer Narrative
Reported event: an event regarding loosening involving a triathlon baseplate was reported.The event was not confirmed.Method & results: -product evaluation and results: visual inspection: visual inspection of the returned device indicated that the entire distal side of the baseplate is covered in bone cement.Based on visual inspection, the loosening event cannot be confirmed as the cement appears well-adhered.-clinician review: a review of the provided medical information by a clinical consultant indicated: "this inquiry concerns a patient who underwent a medial compartment partial knee arthroplasty in 2010 and subsequently required revision surgery in 2021.Initially it was felt that revision was needed for tibial loosening.At the time of the revision, it was found that the femoral component was fractured.In my opinion, the femoral fracture could have been seen prior to the revision.It was present on the lateral x-ray provided.I can confirm that this event happened since i was able to see the x-ray and intraoperative photo showing the fractured femoral component.The loosening of the tibial component is less clear shown.The root cause of this event cannot be determined with certainty.Causes of aseptic loosening after 10 years are multifactorial.These include surgical technique factors and patient factors, including bmi and activity level.Causes of femoral component fracture are also multifactorial.Fracture can occur by fatigue if fixation was solid in one area and not in another.Surgical technique therefore can be contributory.In this particular case i saw very little cement if any anteriorly and no cement posteriorly on the femoral component.This possibly could cause a fatigue effect resulting in fracture." -product history review: review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.-complaint history review: there have been no other similar events for the lot referenced.Conclusions: it was reported that the patient was revised due to tibial loosening, and, intraoperatively, fracture of the femoral component was observed.Visual inspection of the returned device indicated that the entire distal side of the baseplate is covered in bone cement.Based on visual inspection, the loosening event cannot be confirmed as the cement appears well-adhered.A review of the provided medical information by a clinical consultant indicated "initially it was felt that revision was needed for tibial loosening.At the time of the revision, it was found that the femoral component was fractured.In my opinion, the femoral fracture could have been seen prior to the revision.It was present on the lateral x-ray provided.I can confirm that this event happened since i was able to see the x-ray and intraoperative photo showing the fractured femoral component.The loosening of the tibial component is less clear shown.The root cause of this event cannot be determined with certainty.Causes of aseptic loosening after 10 years are multifactorial.These include surgical technique factors and patient factors, including bmi and activity level." no further investigation for this event is possible at this time.If additional information becomes available to indicate further evaluation is warranted, this record will be reopened.
 
Event or Problem Description
The patient received a removal of the sled prosthesis due to aseptic loosening on (b)(6) 2021.During removal of the sled prosthesis, it was noticed that the femoral part was broken.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIATHLON PKR BASEPLATE #5 LM/RL
Common Device Name
PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer Contact
arokiya raj
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key13575705
Report Number0002249697-2022-00264
Device Sequence Number17524602
Product Code HRY
UDI-Device Identifier07613327015560
UDI-Public07613327015560
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K071881
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2010
Device Explanted Year2021
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/20/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date01/31/2015
Device Model Number5620-B-501
Device Catalogue Number5620-B-501
Device Lot NumberAGZAA
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/27/2022
Supplement Date Received by Manufacturer08/25/2022
Initial Report FDA Received Date02/22/2022
Supplement Report FDA Received Date09/20/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/12/2010
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient Age73 YR
Patient SexUnknown
Patient Weight106 KG
-
-