Model Number 1516-50-412
Medical Device Problem Code Unintended Movement (3026)
Health Effect - Clinical Codes Fall (1848); Pain (1994); Unspecified Musculoskeletal problem (4535)
Date of Event 02/09/2022
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that this patient had a right total knee that was painful.The patient was noncompliant and had multiple falls.The patient had blown out her mcl and patella tendon.When the surgeon opened the knee up, it was discovered that the tibial insert has spun 180deg backwards and the patient had been walking with the knee insert in this position.The components are well fixed, so the surgeon did an insert exchange.There is no surgical delay.Doi: (b)(6) 2019; dor: (b)(6) 2022; affected side: right knee.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that this patient had a right total knee that was painful.The patient was noncompliant and had multiple falls.The patient had blown out her mcl and patella tendon.When the surgeon opened the knee up, it was discovered that the tibial insert has spun 180deg backwards and the patient had been walking with the knee insert in this position.The components are well fixed, so the surgeon did an insert exchange.There is no surgical delay.Doi: (b)(6) 2019; dor: (b)(6) 2022; affected side: right knee.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.Device history lot : the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ATTUNE PS RP INSRT SZ 4 12MM
Common Device Name
ATTUNE IMPLANT : KNEE TIBIAL INSERT
Manufacturer (Section D)
DEPUY IRELAND - 9616671
loughbeg ringaskiddy co.
cork
EI 
Manufacturer (Section G)
DEPUY IRELAND 9616671
loughbeg, ringaskiddy co.
cork
EI  
Manufacturer Contact
kara ditty-bovard
700 orthopaedic dr.
warsaw, IN 46581-0988
6107428552
MDR Report Key13576598
Report Number1818910-2022-03249
Device Sequence Number5680528
Product Code NJL
UDI-Device Identifier10603295052333
UDI-Public10603295052333
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
P830055
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2019
Device Explanted Year2022
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 02/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number1516-50-412
Device Catalogue Number151650412
Device Lot Number9214476
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/09/2022
Supplement Date Received by Manufacturer03/23/2022
Initial Report FDA Received Date02/22/2022
Supplement Report FDA Received Date03/24/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured08/13/2019
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ATTUNE PS RP INSRT SZ 4 12MM; UNK ATTUNE FEMORAL
Outcome Attributed to Adverse Event Required Intervention;
Patient Age52 YR