COOK INC FLEXOR ANSEL GUIDING SHEATH; DYB INTRODUCER, CATHETER Back to Search Results
Model Number G44154
Medical Device Problem Codes Break (1069); Peeled/Delaminated (1454); Unraveled Material (1664)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/11/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Initial reporter occupation = director.This report includes information known at this time.A follow-up report will be submitted should additional relevant information become available.
 
Event or Problem Description
As reported, during an unspecified procedure involving placement of a stent, material came out of a flexor ansel guiding sheath when the stent was removed from the sheath.Another manufacturer's 6 french sheath was to be exchanged for the complaint device.After the sheath and dilator were initially flushed, the dilator would only advance about five centimeters when the user attempted to insert it into the sheath.The sheath was flushed again and the sheath and dilator were assembled.The device was inserted into the femoral artery without difficulty, and was then advanced to the contralateral femoral artery.Resistance was not encountered.The other manufacturer's stent passed through the sheath; however, when the stent was removed, part of the sheath came out with the stent.The sheath was removed and another device of the same type was used to complete the procedure and successfully place the stent.A section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.
 
Event or Problem Description
Upon return and initial evaluation of the device, the inner coil was noted to be unraveled and exiting the sheath's hub.
 
Additional Manufacturer Narrative
Blank fields on this form indicate the information is unknown, unavailable, or unchanged.H3: device evaluated by mfg = other (81) - device evaluation has begun; however, a conclusion is not yet available.This report includes information known at this time.A follow-up report will be submitted should additional relevant information become available.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Additional Manufacturer Narrative
Summary of event: as reported, during an unspecified procedure involving placement of a stent, material came out of a flexor ansel guiding sheath when the stent was removed from the sheath.Another manufacturer's 6 french sheath was to be exchanged for the complaint device.After the sheath and dilator were initially flushed, the dilator would only advance about five centimeters when the user attempted to insert it into the sheath.The sheath was flushed again, and the sheath and dilator were assembled.The device was inserted into the femoral artery without difficulty and was then advanced to the contralateral femoral artery.Resistance was not encountered.The other manufacturer's stent passed through the sheath; however, when the stent was removed, part of the sheath came out with the stent.The sheath was removed, and another device of the same type was used to complete the procedure and successfully place the stent.A section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.Upon return and initial evaluation of the device, the inner coil was noted to be unraveled and exiting the sheath's hub.Corrected information: h6 (annex a).Investigation evaluation: reviews of the complaint history, device history record, drawing, instructions for use (ifu), manufacturing instructions, dimensional verification, and quality control procedures were conducted during the investigation.A visual inspection of the complaint device was also conducted.The complaint device was returned to cook for investigation.A kink was noted eight millimeters from the end of the white cap.The inner coil was exiting from the check-flo valve.The device was measured within specification.A document-based investigation evaluation was performed.No related non-conformances were found, and there have been no other reported complaints for this lot number.The product ifu warns ¿reinsertion of dilator prior to removal of flexor sheath increases the strength of the sheath and lessens the risk of device separation.If resistance is anticipated or encountered during withdrawal of flexor sheath, consider carefully reinserting the dilator prior to continuing removal.¿ the information provided upon review of the dmr, dhr, ifu, and investigation of the returned device suggests that there is evidence the device was manufactured to specification.There is no evidence of non-conforming devices in-house or in the field.Cook has concluded that sufficient inspection activities are in place to identify this failure mode prior to distribution.Based on the information provided and the results of the investigation, cook has concluded that a cause for the event could not be established.The risk analysis for this failure mode was reviewed and no additional escalation was required.There is currently a capa investigation open to investigate this product failure mode.The appropriate personnel have been notified and cook will continue to monitor for similar events.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Event or Problem Description
No additional information has been received since the last report was submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FLEXOR ANSEL GUIDING SHEATH
Common Device Name
DYB INTRODUCER, CATHETER
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer (Section G)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer Contact
jason crouch
750 daniels way
bloomington, IN 47404
8123392235
MDR Report Key13578946
Report Number1820334-2022-00282
Device Sequence Number5731071
Product Code DYB
UDI-Device Identifier00827002441545
UDI-Public(01)00827002441545(17)241216(10)14424730
Combination Product (Y/N)N
Initial Reporter StateKS
Initial Reporter CountryUS
PMA/510(K) Number
K142829
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 06/10/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/16/2024
Device Model NumberG44154
Device Catalogue NumberKCFW-6.0-18/38-45-RB-ANL0-HC
Device Lot Number14424730
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/15/2022
Supplement Date Received by Manufacturer03/18/2022
06/07/2022
Initial Report FDA Received Date02/22/2022
Supplement Report FDA Received Date04/06/2022
06/10/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured12/16/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
BARD CROSSOVER 6X10 SHEATH, SUPERA STENT.
Patient SexUnknown
-
-