Model Number M00326310
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 01/27/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The device is not available to the manufacturer.
 
Event or Problem Description
It was reported that during the stroke treatment when physician delivered the balloon after crossing the tight stenosis, the tip of the subject guidewire was fractured inside the patient's anatomy.Attempts were made to retrieve the broken tip but the physician was unsuccessful and was left inside the patient.The procedure was completed successfully.No clinical consequences were reported to the patient due to this event.
 
Additional Manufacturer Narrative
The device is not available to the manufacturer.
 
Event or Problem Description
It was reported that during the stroke treatment when physician delivered the balloon after crossing the tight stenosis, the tip of the subject guidewire was fractured inside the patient's anatomy.Attempts were made to retrieve the broken tip but the physician was unsuccessful and was left inside the patient.The procedure was completed successfully.No clinical consequences were reported to the patient due to this event.
 
Additional Manufacturer Narrative
There are controls in the manufacturing process to ensure the product met specifications upon release.The subject device is not available; therefore, functional testing as well as visual testing cannot be performed.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.The reported complaint could not be confirmed, and it could not be definitively determined if the device failed to meet specifications because the product was not returned.It was reported that during the procedure, the tip of the subject guidewire got fractured and was left inside the patient's anatomy after attempts to retrieve the wire failed.The wire was stented down with non-stryker device that was already needed in the procedure for stenosis.While there are a number of potential causes for the reported issue, because review and analysis of available information failed to identify a definitive cause and the device was not returned, an assignable cause of undeterminable was assigned to this complaint of guidewire distal tip broken/fractured during use' and 'un-retrieved device fragments'.
 
Event or Problem Description
It was reported that during the stroke treatment when physician delivered the balloon after crossing the tight stenosis, the tip of the subject guidewire was fractured inside the patient's anatomy.Attempts were made to retrieve the broken tip but the physician was unsuccessful and was left inside the patient.The procedure was completed successfully.No clinical consequences were reported to the patient due to this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNCHRO2-14 SOFT STRAIGHT 300CM
Common Device Name
WIRE, GUIDE, CATHETER
Manufacturer (Section D)
STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY
4870 west 2100 south
salt lake city UT 84120
Manufacturer (Section G)
STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY
4870 west 2100 south
salt lake city UT 84120
Manufacturer Contact
tara lopez
47900 bayside parkway
fremont, CA 94538
5104132500
MDR Report Key13579319
Report Number3012931345-2022-00032
Device Sequence Number14907339
Product Code DQX
UDI-Device Identifier04546540688743
UDI-Public04546540688743
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K053268
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 05/10/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/15/2023
Device Model NumberM00326310
Device Catalogue NumberM00326310
Device Lot Number0000054642
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/02/2022
Supplement Date Received by Manufacturer04/13/2022
Initial Report FDA Received Date02/22/2022
Supplement Report FDA Received Date05/10/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured11/16/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ACCLINO STENT (ACANDIS); CORONARY BALLOON (UNKNOWN)
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-