| Model Number |
10094141 |
| Medical Device Problem Code |
Radiation Output Failure (4027)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/17/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Siemens is conducting a thorough investigation of the reported events.As this event is under investigation, a root cause has not yet been determined.A supplement report will be filed upon completion of the investigation.
|
| |
|
Event or Problem Description
|
|
It was reported to siemens that a malfunction occurred while operating the artis zee biplane system.During an interventional procedure, the user reported that no more x-ray was possible.The procedure was continued and completed on an alternate system.We are unaware of any impact to the state of health of the patient involved.Siemens has requested additional information in order to conduct an investigation of the reported event.
|
| |
|
Additional Manufacturer Narrative
|
|
Siemens is conducting a thorough investigation of the reported events.As this event is under investigation, a root cause has not yet been determined.A supplement report will be filed upon completion of the investigation.
|
| |
|
Event or Problem Description
|
|
It was reported to siemens that a malfunction occurred while operating the artis zee biplane system.During an interventional procedure, the user reported that no more x-ray was possible.The procedure was continued and completed on an alternate system.We are unaware of any impact to the state of health of the patient involved.Siemens has requested additional information in order to conduct an investigation of the reported event.
|
| |
|
Additional Manufacturer Narrative
|
|
Siemens has completed an investigation of the reported event.Assessment does not indicate a system failure or malfunction and no non-conformity was identified.The investigation revealed that the in-house power supply had been interrupted.The investigation did not reveal the reason of the power supply issue.To prevent a power loss on the siemens system, an uninterruptible power supply (ups) is connected upstream.Unfortunately, the ups was faulty and did not provide power to the generator.The system was brought back into operation after the power outage was resolved and the manufacturer of the ups was informed.No deficiency at the siemens system was found and the system works as specified.
|
| |
|