Model Number 142122-15
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Restenosis (4576)
Date of Event 12/01/2021
Type of Reportable Event Serious Injury
Event or Problem Description
There is no evidence to suggest that the device caused or contributed to this event.The patient was treated as part of the mimics 3d usa post-market observational study on (b)(6) 2021 to treat a denovo occlusion in the sfa proximal third to sfa middle third of the left leg.An event of restenosis of treated segment (target lesion) was originally reported to veryan on 04 feb 2022 as "not related" to the device or procedure.It was reported with the following comment "subject had complaints of recurrent severe claudication symptoms of bilateral lower extremity with mild rest pain and severe calf claudication.Angiogram showed 80% in-stent restenosis." the event was reviewed internally at a veryan safety review meeting on 07 feb 2022 and confirmed by veryan's chief medical officer that based on the in-stent restenosis, it is possibly device-related.The outcome of the event is reported as resolved/recovered.The device remains implanted.
 
Additional Manufacturer Narrative
There was no reported device malfunction and the device was not returned for analysis.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Based on the case information and related record review, a conclusive cause for the reported patient effects, and the relationship to the product, if any, cannot be determined.The reported patient effect of restenosis leading to additional surgical intervention is listed in the biomimics 3d instructions for use and is a known patient effect of peripheral stenting procedures.There is no indication of a product quality issue with respect to the design, manufacture or labelling of the device.If further information regarding this event becomes available, a follow-up report will be submitted.
 
Event or Problem Description
There is no evidence to suggest that the device caused or contributed to this event.The patient was treated as part of the mimics 3d usa post-market observational study on (b)(6) 2021 to treat a denovo occlusion in the sfa proximal third to sfa middle third of the left leg.An event of restenosis of treated segment (target lesion) was originally reported to veryan on 04 feb 2022 as "not related" to the device or procedure.It was reported with the following comment "subject had complaints of recurrent severe claudication symptoms of bilateral lower extremity with mild rest pain and severe calf claudication.Angiogram showed 80% in-stent restenosis." the event was reviewed internally at a veryan safety review meeting on 07 feb 2022 and confirmed by veryan's chief medical officer that based on the in-stent restenosis, it is possibly device-related.The outcome of the event is reported as resolved/recovered.The device remains implanted.
 
Additional Manufacturer Narrative
There was no reported device malfunction and the device was not returned for analysis.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Based on the case information and related record review, a conclusive cause for the reported patient effects, and the relationship to the product, if any, cannot be determined.The reported patient effect of restenosis leading to additional surgical intervention is listed in the biomimics 3d instructions for use and is a known patient effect of peripheral stenting procedures.There is no indication of a product quality issue with respect to the design, manufacture or labelling of the device.If further information regarding this event becomes available, a follow-up report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BIOMIMICS 3D VASCULAR STENT SYSTEM
Common Device Name
BIOMIMICS 3D VASCULAR STENT SYSTEM
Manufacturer (Section D)
VERYAN MEDICAL LTD
unit 11 galway technology park
parkmore road
galway city, H91 V E0H
EI  H91 VE0H
Manufacturer Contact
alan mcdonagh
unit 11 galway technology park
parkmore road
galway, H91 V-EOH
EI   H91 VEOH
MDR Report Key13598166
Report Number3011632150-2022-00009
Device Sequence Number13945418
Product Code NIP
UDI-Device Identifier05391526850497
UDI-Public(01)05391526850497(17)220320(11)200819(10)0000049876
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P180003
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Study,Health Professional
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 02/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date03/20/2022
Device Model Number142122-15
Device Catalogue Number142122-15
Device Lot Number0000049876
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/07/2022
Initial Report FDA Received Date02/25/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured08/19/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ASPIRIN; CLOPIDOGREL (PLAVIX)
Outcome Attributed to Adverse Event Other;
Patient Age75 YR
Patient SexMale
Patient Weight95 KG
Patient EthnicityNon Hispanic