• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BARD PERIPHERAL VASCULAR, INC. ULTRAVERSE 035; PTA BALLOON DILATATION CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BARD PERIPHERAL VASCULAR, INC. ULTRAVERSE 035; PTA BALLOON DILATATION CATHETER Back to Search Results
Model Number U3575530
Medical Device Problem Codes Difficult to Remove (1528); Material Deformation (2976)
Health Effect - Clinical Code Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 01/28/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
As the lot number for the device was provided, a review of the device history record is currently being performed.The device has been returned to the manufacturer for evaluation.The investigation of the reported event is currently underway.(expiry date: 05/2023).
 
Event or Problem Description
It was reported that during an angioplasty procedure through the superficial femoral artery to treat the lower limb, the distal part of the balloon caught on the sheath and was unable to remove from the patient after deflation.It was further reported that physician pulled the balloon from the patient very hard which caused the arterial damage.Another sheath was used to tamponade the damaged artery and the patient was reported to be in stable condition.
 
Additional Manufacturer Narrative
As the lot number for the device was provided, a review of the device history record is currently being performed.The device has been returned to the manufacturer for evaluation.The investigation of the reported event is currently underway.(expiry date: 05/2023).
 
Event or Problem Description
It was reported that during an angioplasty procedure through the superficial femoral artery to treat the lower limb, the distal part of the balloon caught on the sheath and was unable to remove from the patient after deflation.It was further reported that physician pulled the balloon from the patient very hard which caused the arterial damage.Another sheath was used to tamponade the damaged artery and the patient was reported to be in stable condition.
 
Event or Problem Description
It was reported that during an angioplasty procedure through the superficial femoral artery to treat the lower limb, the distal part of the balloon caught on the sheath and was unable to remove from the patient after deflation.It was further reported that physician pulled the balloon from the patient very hard which caused the arterial damage.Another sheath was used to tamponade the damaged artery and the patient was reported to be in stable condition.
 
Additional Manufacturer Narrative
H10: manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this product and lot.Investigation summary: one ultraverse 035 pta dilatation catheter was received for evaluation.During visual evaluation, no kinks were noted to the catheter shaft and no anomalies to the luers/y-body.No bends were noted to the catheter.The distal tip of the balloon was noted to be prolapsed.The returned unknown sheath was noted to be buckled at the distal tip and bends were noted throughout.During functional testing, the sample guidewire lumen was flushed.The patency of the guidewire lumen was tested using an in-house guidewire and was able to be inserted without issues.An in-house syringe was used flush the in-house introducer sheath without any issues.The balloon was unable to be fully inserted.No other functional testing was performed.Therefore, the investigation is confirmed for the reported difficult to remove as the distal tip of the balloon was noted to be prolapsed and the unknown sheath was buckled at its distal tip during visual evaluation of returned sample.A definitive root cause for the alleged failure to remove could not be determined based upon the provided information.Labeling review: a review of product labeling documentation (e.G., procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.H10: d4 (expiry date: 05/2023), g3, h6 (method).H11: h6 (result, conclusion).H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : see h10.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRAVERSE 035
Common Device Name
PTA BALLOON DILATATION CATHETER
Manufacturer (Section D)
BARD PERIPHERAL VASCULAR, INC.
1625 w 3rd st.
tempe AZ 85281
Manufacturer (Section G)
CLEARSTREAM TECHNOLOGIES LTD.
moyne upper
enniscorthy, co. wexford N A
EI   N A
Manufacturer Contact
judy ludwig
800 w. rio salado pkwy
tempe, AZ 85281
4803032689
MDR Report Key13598536
Report Number2020394-2022-00128
Device Sequence Number5947080
Product Code LIT
UDI-Device Identifier00801741092534
UDI-Public(01)00801741092534
Combination Product (Y/N)N
Initial Reporter CountrySN
PMA/510(K) Number
K142261
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 03/24/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberU3575530
Device Catalogue NumberU3575530
Device Lot NumberCMET0496
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/22/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/28/2022
Supplement Date Received by Manufacturer04/01/2022
Initial Report FDA Received Date02/25/2022
Supplement Report FDA Received Date04/05/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-