MAUDE Adverse Event Report: ETHICON ENDO-SURGERY, LLC. PROXIMATE*55MM LINEAR CUTTER; STAPLE, IMPLANTABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON ENDO-SURGERY, LLC. PROXIMATE*55MM LINEAR CUTTER; STAPLE, IMPLANTABLE Back to Search Results
Model Number TLC55
Medical Device Problem Codes Failure to Fire (2610); Mechanical Jam (2983)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/01/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Pc-(b)(4).Batch # 385a93.Device analysis: the product was returned to ethicon endo-surgery for evaluation.Visual inspection and functional testing were conducted on the returned device.Visual analysis of the returned sample revealed that the tlc55 device was received with no apparent damage, with no reload present.The device was tested for functionality with a test reload and it fired, cut, formed all the staples as intended and the knife returned to the home position as expected.The staple line and cut line were complete, and the staples meet the staple form release criteria.As part of ethicon endo surgery¿s quality process, all devices are manufactured, inspected, and released to approved specifications.Although no conclusion could be reached on the cause of the reported event, the instructions for use do contain the following caution: place the instrument across the tissue for transection or into the lumen to form an anastomosis.For instruments with no knife, place the instrument across the tissue to be stapled.With the alignment/locking lever in the completely opened position, join the instrument halves together by aligning from either the front, center or back of the instrument.To adjust tissue on the forks before firing, move the alignment/locking lever to the intermediate position.This allows maneuvering of the tissue while the instrument halves are joined.Close the alignment/locking lever completely when the tissue is properly in place.To fire the linear cutter, place the thumb on the firing knob and two fingers on the shoulders of the linear cutter.Fire the instrument by pushing the firing knob completely forward.Completely return the firing knob to the original ¿return knob here¿ position.Separate the instrument halves by opening the alignment/locking lever and remove the instrument.The event described could not be confirmed as the device performed without any difficulties.A manufacturing record evaluation was performed for the finished device batch number, and no non-conformances were identified.Additional information was requested but not available: could you please provide more details for "the blade got stuck"? did the reload lock out and would not work? did the reload begin to staple and cut, but then jammed? did the device staple? if the device stapled, was the staple line complete? if the device stapled, what was the shape of the staples (b-formation, irregular, legs straight)? did the device cut? if the device cut, was the cut line complete? were the cut line and staple lines equal? did the device staple, but there was no cut line? did the knife did not return?.
 
Event or Problem Description
It was reported that during the unknown procedure, while the surgery resident was firing stapler, the blade got stuck.He was able to separate stapler pieces to remove from bowel.There was no patient harm.
 
Additional Manufacturer Narrative
(b)(4).Batch # 385a93.Device analysis: the product was returned to ethicon endo-surgery for evaluation.Visual inspection and functional testing were conducted on the returned device.Visual analysis of the returned sample revealed that the tlc55 device was received with no apparent damage, with no reload present.The device was tested for functionality with a test reload and it fired, cut, formed all the staples as intended and the knife returned to the home position as expected.The staple line and cut line were complete, and the staples meet the staple form release criteria.As part of ethicon endo surgery¿s quality process, all devices are manufactured, inspected, and released to approved specifications.Although no conclusion could be reached on the cause of the reported event, the instructions for use do contain the following caution: place the instrument across the tissue for transection or into the lumen to form an anastomosis.For instruments with no knife, place the instrument across the tissue to be stapled.With the alignment/locking lever in the completely opened position, join the instrument halves together by aligning from either the front, center or back of the instrument.To adjust tissue on the forks before firing, move the alignment/locking lever to the intermediate position.This allows maneuvering of the tissue while the instrument halves are joined.Close the alignment/locking lever completely when the tissue is properly in place.To fire the linear cutter, place the thumb on the firing knob and two fingers on the shoulders of the linear cutter.Fire the instrument by pushing the firing knob completely forward.Completely return the firing knob to the original ¿return knob here¿ position.Separate the instrument halves by opening the alignment/locking lever and remove the instrument.The event described could not be confirmed as the device performed without any difficulties.A manufacturing record evaluation was performed for the finished device batch number, and no non-conformances were identified.Additional information was requested but not available: could you please provide more details for "the blade got stuck"? did the reload lock out and would not work? did the reload begin to staple and cut, but then jammed? did the device staple? if the device stapled, was the staple line complete? if the device stapled, what was the shape of the staples (b-formation, irregular, legs straight)? did the device cut? if the device cut, was the cut line complete? were the cut line and staple lines equal? did the device staple, but there was no cut line? did the knife did not return?.
 
Event or Problem Description
It was reported that during the unknown procedure, while the surgery resident was firing stapler, the blade got stuck.He was able to separate stapler pieces to remove from bowel.There was no patient harm.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Common Device Name
STAPLE, IMPLANTABLE
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
*  00969
Manufacturer (Section G)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
*   00969
MDR Report Key13598782
Report Number3005075853-2022-01127
Device Sequence Number1930063
Product Code GDW
UDI-Device Identifier10705036013204
UDI-Public10705036013204
Combination Product (Y/N)N
PMA/510(K) Number
K020779
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 02/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/28/2026
Device Model NumberTLC55
Device Catalogue NumberTLC55
Device Lot Number396A19
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/21/2022
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/31/2022
Initial Report FDA Received Date02/25/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/28/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Patient Sequence Number1
Patient SexUnknown
-
-