MAUDE Adverse Event Report: STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON #3 CR INSERT 13MM; PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON #3 CR INSERT 13MM; PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO Back to Search Results
Model Number 5530-P-313
Medical Device Problem Code Degraded (1153)
Health Effect - Clinical Code Ambulation or Postural Difficulties (2544)
Date of Event 02/01/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Device noted as returned.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.
 
Event or Problem Description
It was reported that the patient's right knee was revised.Intra-operatively, the posterior aspect of the medial condyle of the femoral component was broken from the rest of the implant, resulting in damage to the insert.A size 3 cr femur and size 3 cr insert were revised to a size 4 ts femur and another insert.Incident occurred during a revision total knee arthroplasty in which the femoral component (5510-f-402) was fractured at the medial distal surface.As well as significant wear on the medial bearing surface of the polyethylene.The tibial baseplate (5520-b-300) remained well-fixed, therefore was not revised.The femoral component was revised with a rt ts size 4 femur comprised of a 5mm augment distal medial, 5mm augment posterior medial, and a 15mm x 50mm cemented stem.The polyethylene was revised with a size 3 x 16mm posterior stabilized insert.
 
Event or Problem Description
It was reported that the patient's right knee was revised.Intra-operatively, the posterior aspect of the medial condyle of the femoral component was broken from the rest of the implant, resulting in damage to the insert.A size 3 cr femur and size 3 cr insert were revised to a size 4 ts femur and another insert.Update:incident occurred during a revision total knee arthroplasty in which the femoral component (5510-f-402) was fractured at the medial distal surface.As well as significant wear on the medial bearing surface of the polyethylene.The tibial baseplate (5520-b-300) remained well-fixed, therefore was not revised.The femoral component was revised with a rt ts size 4 femur comprised of a 5mm augment distal medial, 5mm augment posterior medial, and a 15mm x 50mm cemented stem.The polyethylene was revised with a size 3 x 16mm posterior stabilized insert.
 
Additional Manufacturer Narrative
Reported event: an event regarding damage involving a triathlon insert was reported.The event was confirmed via evaluation of the returned device.Method & results: -product evaluation and results: visual inspection of the returned device indicated that the device was severely damaged on the surface against which the femoral component articulates.Damage to the insert is consistent with contact with the fractured portion of the femoral component.Additional damage to the locking mechanism of the insert is also observed; this damage is consistent with attempted explantation.-clinician review: a review of the provided medical records by a clinical consultant indicated: this inquiry reports the revision of a total knee arthroplasty on (b)(6), 2022 for fracture of the femoral component.No implant date was reported.I cannot confirm that this event took place since i was not able to see any documentation such as office notes, revision operation notes, photos of explants and complete preop and post op radiographs.Regarding the possible root cause of this event, i cannot determine it with certainty.Causes of fracture of a femoral component are multifactorial including surgical technique factors, patient activity factors (such as height, weight, activity level and bmi), and implant factors.-product history review: review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.-complaint history review: there have been no other similar events for the lot referenced.Conclusions: it was reported that significant wear on the medial bearing surface of the polyethylene.Visual inspection of the returned device indicated that the device was severely damaged on the surface against which the femoral component articulates.Damage to the insert is consistent with contact with the fractured portion of the femoral component.Additional damage to the locking mechanism of the insert is also observed; this damage is consistent with attempted explantation.The exact cause of the event could not be determined because insufficient information was provided.Further information such as office notes, revision operation notes, and complete preop and post op radiographs.Are needed to complete the investigation for determining root cause.No further investigation for this event is possible at this time.If additional information becomes available to indicate further evaluation is warranted, this record will be reopened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIATHLON #3 CR INSERT 13MM
Common Device Name
PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-LIMERICK
raheen business park
limerick NA
EI   NA
Manufacturer Contact
arokiya raj
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key13610244
Report Number0002249697-2022-00283
Device Sequence Number1969033
Product Code MBH
UDI-Device Identifier07613327041743
UDI-Public07613327041743
Combination Product (Y/N)N
Initial Reporter StateNC
Initial Reporter CountryUS
PMA/510(K) Number
K040267
Number of Events Summarized1
Summary Report (Y/N)N
Device Explanted Year2022
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 05/17/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date05/31/2014
Device Model Number5530-P-313
Device Catalogue Number5530P313
Device Lot NumberLBN834
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/24/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/01/2022
Supplement Date Received by Manufacturer04/26/2022
Initial Report FDA Received Date02/26/2022
Supplement Report FDA Received Date05/17/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/21/2009
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age74 YR
Patient SexFemale
Patient Weight64 KG
-
-