| Model Number |
420227-11 |
| Medical Device Problem Code |
Material Split, Cut or Torn (4008)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/19/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Isi has not received the pk dissecting forceps instrument for evaluation.Therefore, the root cause of the customer reported failure mode has not been determined.A follow-up mdr will be submitted if additional information is obtained.A review of the site's complaint history does not show any additional complaints related to this product and/or this event.A review of the instrument log for the instrument (pn 420227-11/lot # n11191202 752) associated with this event was performed.Per logs, the instrument was last used on (b)(6) 2022 on system (b)(4).The instrument had no uses remaining after last use.Based on the information provided at this time, this complaint is being reported due to the following conclusion: it was alleged that the instrument had conductor wire damage.The damaged/broken conductor wire has potential for electrical discharge at a location other than intended.While there was no harm or injury to the patient, the reported failure mode could likely cause or contribute to an adverse event if it were to recur.
|
| |
|
Event or Problem Description
|
|
It was reported that prior to starting a da vinci-assisted radical prostatectomy with lymphadenectomy surgical procedure, the power cable of the pk dissecting forceps instrument was torn.The procedure was completed with no reported injury.Intuitive surgical, inc.(isi) made multiple follow up attempts to obtain additional information, however, no further details have been received as of date of this report.
|
| |
|
Event or Problem Description
|
|
Refer to h10/h11 for follow-up information.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information can be found in the following fields: d9, g3, g6, h2, and h3 failure analysis investigation can be found in the following fields: h6 and h10 intuitive surgical, inc.(isi) received the pk dissecting forceps involved with this complaint and completed the device evaluation.Failure analysis confirmed the customer reported complaint.Failure analysis found the primary failure of the broken conductor wire to be related to the customer reported complaint.The pk dissecting forceps instrument was found to have a broken conductor wire at the yaw pulley at the distal end.The conductor wire was broken at the grip-crimp location and the root cause was attributed to a component failure.
|
| |
|