Model Number PCDN1
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Adhesion(s) (1695); Diarrhea (1811); Inflammation (1932); Nausea (1970); Pain (1994); Perforation (2001); Chills (2191); Weight Changes (2607); Decreased Appetite (4569)
Event Type  Injury  
Manufacturer Narrative
To date, the device has not been returned.If the product is returned for evaluation, any further information derived from the evaluation will be submitted in a supplemental 3500a form.
 
Event Description
It was reported by an attorney that the patient underwent hernia repair surgery on (b)(6) 2013 and mesh was implanted.It was reported that the patient underwent revision surgery on an unk date.It was reported that the patient experienced extensive adhesions, bowel perforation, severe pain, nausea, diarrhea, chills, inflammation, loss of appetite and extreme weight loss.No additional information was provided.
 
Manufacturer Narrative
Date sent to the fda: 3/17/2022.Additional information: d4, h4.A review of the batch manufacturing records was conducted and the batch met all finished goods release criteria.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Type of Device
MESH, SURGICAL, POLYMERIC
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
ETHICON INC.-CORNELIA
655 ethicon circle
cornelia GA 30531
Manufacturer Contact
elba bello
1000 route 202
raritan, NJ 08869
MDR Report Key13615312
MDR Text Key290449918
Report Number2210968-2022-01361
Device Sequence Number1
Product Code FTL
UDI-Device Identifier10705031047761
UDI-Public10705031047761
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K060713
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 02/27/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date06/30/2014
Device Model NumberPCDN1
Device Catalogue NumberPCDN1
Device Lot NumberEHG204
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 02/24/2022
Initial Date FDA Received02/27/2022
Supplement Dates Manufacturer Received03/15/2022
Supplement Dates FDA Received03/18/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/02/2012
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;