• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (BASD) -3006260740 HICKMAN CV CATHETER, DUAL-LUMEN,12F; CHRONIC CATHETERS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (BASD) -3006260740 HICKMAN CV CATHETER, DUAL-LUMEN,12F; CHRONIC CATHETERS Back to Search Results
Model Number 0600620
Medical Device Problem Codes Burst Container or Vessel (1074); Fluid/Blood Leak (1250); Fracture (1260); Obstruction of Flow (2423)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/24/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that seven months and four days post chronic catheter placement procedure in the right internal jugular vein, the device allegedly fractured.It was further reported that lumen allegedly blocked during flushing.The device was repaired.There was no reported patient injury.
 
Additional Manufacturer Narrative
As the lot number for the device was not provided, a review of the device history record could not be performed.The device has been returned to the manufacturer for evaluation.The investigation of the reported event is currently underway.
 
Additional Manufacturer Narrative
H10: manufacturing review: a manufacturing review was not requested as the lot number reported is unknown.Investigation summary: one 12fr hickman d/l catheter was returned for evaluation.Gross visual, microscopic, tactile and functional testing were performed.The investigation is confirmed for the reported leak, fracture, obstruction of flow and identified burst issues as a c-shaped split was noted on the white luer extension leg approximately 1.0cm from the clamping sleeve.A longitudinal split was noted on the red luer extension leg approximately 0.6cm from the clamping sleeve.During tactile evaluation, extension legs and catheter were gently stretched and necking was observed throughout.All areas were noted to be normally elastic.Upon infusion of the white luer, a leak from the c-shaped split was noted while water exited the distal end of the catheter; only air was aspirated into the syringe.Thrombus was observed exiting the catheter on both infusion attempts.The definitive root cause could not be determined based upon available information.Labeling review: a review of product labeling documentation (e.G.Procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.H10: b5, g3, h6(device, method).H11: h6(result, conclusion).H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : see h10.
 
Event or Problem Description
It was reported that approximately seven months post chronic catheter placement procedure in the right internal jugular vein, the device allegedly fractured.It was further reported that lumen allegedly blocked during flushing.Reportedly leak was noted on the white luer of the catheter.The device was repaired.There was no reported patient injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HICKMAN CV CATHETER, DUAL-LUMEN,12F
Common Device Name
CHRONIC CATHETERS
Manufacturer (Section D)
C.R. BARD, INC. (BASD) -3006260740
605 north 5600 west
salt lake city 84116
Manufacturer (Section G)
BARD SHANNON LIMITED -3005636544
san geronimo industrial park
lot #1, road #3, km 79.7
humacao PR 00791
Manufacturer Contact
judy ludwig
800 w. rio salado pkwy
tempe, AZ 85281
4803032689
MDR Report Key13629129
Report Number3006260740-2022-00534
Device Sequence Number5913178
Product Code LJS
UDI-Device Identifier00801741051913
UDI-Public(01)00801741051913
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K830233
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 03/17/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0600620
Device Catalogue Number0600620
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/14/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/02/2022
Supplement Date Received by Manufacturer03/22/2022
Initial Report FDA Received Date03/01/2022
Supplement Report FDA Received Date03/26/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexFemale
-
-