Model Number SEP6
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/10/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This device is available for return.A follow up mdr will be submitted upon completion of the device investigation.
 
Event or Problem Description
The patient was undergoing a thrombectomy procedure to treat a bilateral critical ischemia of the external iliac artery using an indigo system aspiration catheter 6 (cat6) and an indigo system separator 6 (sep6).During the procedure the physician completed approximately ten passes using the cat6 and sep6.Upon removal of the cat6 and the sep6, it was noticed that the bulb of the sep6 was missing.It was reported that the physician could not locate the bulb of the sep6 by sight or via fluoroscopy.The physician continued the procedure using an indigo system aspiration catheter 8 (cat8) and an indigo system separator 8 (sep8).It was reported that although the indigo system aspiration catheters unclogged the arteries, the arteries re-clogged just as quickly due to an already organized thrombus.The physician decided to end the procedure at this point.The patient was then put on a curative heparin therapy.There was no report of an adverse effect to the patient.
 
Additional Manufacturer Narrative
Evaluation of the returned sep6 confirmed that the bulb was fractured off the separator¿s distal end.Evaluation also revealed the sep6 core wire was fractured, and the support coil winds were unraveled.It was reported that the device was used for multiple passes.If the device is manipulated against tough clot burden or retracted against resistance, the device may fatigue and subsequently fracture.Penumbra products are inspected during in-process inspection and during quality inspection after manufacturing.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INDIGO SYSTEM SEPARATOR 6
Common Device Name
DXE
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
Manufacturer Contact
veronica farris
one penumbra place
alameda, CA 94502
5107483200
MDR Report Key13636712
Report Number3005168196-2022-00087
Device Sequence Number20134008
Product Code DXE
UDI-Device Identifier00814548016146
UDI-Public00814548016146
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K160533
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 07/27/2022
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/05/2024
Device Model NumberSEP6
Device Catalogue NumberSEP6
Device Lot NumberF106044
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Date Report to Manufacturer01/10/2005
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/01/2022
Supplement Date Received by Manufacturer07/12/2022
Initial Report FDA Received Date03/01/2022
Supplement Report FDA Received Date07/27/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/06/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age64 YR
Patient SexFemale