Model Number CH06-40-75US
Medical Device Problem Codes Deflation Problem (1149); Detachment of Device or Device Component (2907)
Health Effect - Clinical Code Unintended Radiation Exposure (4565)
Date of Event 01/24/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, the physician observed and reported that the balloon was difficult to deflate (just an observation not a quality issue).It was stated that when the balloon was being removed from the patient, the balloon was caught in the introducer sheath (6 french gauge (fr), cordis) and as result the balloon separated from the catheter and was broken into two pieces (the broke in two pieces refer to the catheter as one piece and the balloon as the second piece.The balloon remained intact).The balloon was retrieved without surgical intervention because it broke within the sheath instead of the vessel.It was stated that to resolve the issue the balloon was removed together with the introducer sheath and the procedure was completed.X-ray/ fluoro was required to check if all pieces were accounted for and the balloon was also examined to ensure it was intact.All pieces were retrieved from the patient.The catheter was not repaired.There was no leak and no luer adapter issue.Tego was not utilized.There was nothing unusual observed on the device prior to use, flushing was done per instruction for use (ifu) and there was no unexpected result, no other products were utilized with the device and no other defects/damages were found on the product.There was no resistance encountered when advancing the device, the device did not pass through a previously deployed stent, the reported balloon was inflated by hand with a syringe, the inflation fluid used was standard contrast fluid mix, the device did not move while inflated, no excessive force was used (detachment was spontaneous), and there was no additional medical intervention required to retrieve the detached item.There was no patient symptoms or complications associated with this event.There was no vessel damage, there was no blood loss and blood transfusion was not required.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CHAMELEON
Common Device Name
CATHETER, CONTINUOUS FLUSH
Manufacturer (Section D)
COVIDIEN MFG SOLUTIONS S.A.
edificio b20, calle #2
alajuela 20101
CS  20101
Manufacturer (Section G)
COVIDIEN MFG SOLUTIONS S.A.
edificio b20, calle #2
alajuela 20101
CS   20101
Manufacturer Contact
clay chandler
5920 longbow drive
boulder, CO 80301
3035306409
MDR Report Key13642705
Report Number3009211636-2022-00057
Device Sequence Number4995767
Product Code KRA
UDI-Device Identifier07290016745023
UDI-Public07290016745023
Combination Product (Y/N)N
Initial Reporter StateAL
Initial Reporter CountryUS
PMA/510(K) Number
K170635
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 03/01/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/29/2022
Device Model NumberCH06-40-75US
Device Catalogue NumberCH06-40-75US
Device Lot Number22002937
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/11/2022
Initial Report FDA Received Date03/01/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-