• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: FX SOLUTIONS HUMELOCK REVERSED; REVERSED SHOULDER PROSTHESIS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

FX SOLUTIONS HUMELOCK REVERSED; REVERSED SHOULDER PROSTHESIS Back to Search Results
Model Number 105-3613
Health Effect - Clinical Code Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 12/30/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
This mdr has already been submitted to fda by the us importer with report number 3014128390-2022-00002.
 
Event or Problem Description
The patient was revised for dislocation on (b)(6) 2021.Approximately 3 weeks after the first surgery.The surgeon explanted 1 eccentric glenosphere (36), 1 humeral spacer (9) and 1 humeral cup (36/9).The surgeon implanted 2 cortical screw 26 and 28, 1 humeral spacer (9) and 1 humeral cup (36/6).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HUMELOCK REVERSED
Common Device Name
REVERSED SHOULDER PROSTHESIS
Manufacturer (Section D)
FX SOLUTIONS
1663 rue des majornas
viriat, 01440
FR  01440
Manufacturer (Section G)
FX SOLUTIONS
1663 rue des majornas
viriat, 01440
FR   01440
Manufacturer Contact
ratsamy thevenin
1663 rue des majornas
viriat, 01440
FR   01440
MDR Report Key13652913
Report Number3009532798-2022-00002
Device Sequence Number14073834
Product Code PHX
UDI-Device Identifier03701037300275
UDI-Public03701037300275
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K150488
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2021
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 02/09/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Expiration Date01/11/2022
Device Model Number105-3613
Device Catalogue Number105-3613
Device Lot NumberL1846
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/04/2022
Initial Report FDA Received Date03/02/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization;
Patient SexUnknown
-
-