| Model Number |
86-6022 |
| Medical Device Problem Code |
Device Dislodged or Dislocated (2923)
|
| Health Effect - Clinical Codes |
Fall (1848); Foreign Body Reaction (1868); Pain (1994); Osteolysis (2377); Swelling/ Edema (4577); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
12/14/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Subject id: (b)(6).Study no: (b)(6).Clinical notification received for revision to address stress reaction.Date of implantation: (b)(6) 2003.Date of revision: (b)(6) 2021 (right knee).Treatment: revision of the tibial insert.Clinic visit (b)(6) 2021: patient presents with right knee pain, swelling, warmth, and crepitus after several falls 20 years status post bilateral knee implantation.Radiographic images identify an anteriorly distracted tibial insert and an area of asymptomatic tibial osteolysis.Plan is made to revise the insert, as the tibial and femoral components are well-fixed and intact.Dor: (b)(6) 2021: patient received a right knee insert revision to treat pain and limited range of motion secondary to displacement of the tibial insert.Upon entering the joint, the surgeon identified black stained synovium and performed a complete synovectomy.The insert was displaced anteriorly.The surgeon notes there was no wear or problems with the locking mechanism on the tray.The tray was well-fixed and retained.The issue was resolved by replacing the old insert with a new insert that was one size larger.The insert snapped into position and a rom check confirmed it was not displaceable.The procedure was completed without complications.Doi: unknown.Dor: (b)(6) 2021; right knee.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.Device history lot : the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.
|
| |
|