SMITH & NEPHEW MEDICAL LTD. IV3000 1 HAND 6X7CM CTN 100; TAPE AND BANDAGE, ADHESIVE Back to Search Results
Model Number 66024007
Medical Device Problem Code Defective Device (2588)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/11/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Internal complaint reference: (b)(4).
 
Event or Problem Description
It was reported that, during use, the iv3000 was found unfold and stuck together.It is unknown how the problem was solved.No patient complications reported.
 
Additional Manufacturer Narrative
H10: it was reported that, during use, the iv3000 was found unfold and stuck together.It is unknown how the problem was solved.No patient complications reported.The device was used for treatment and was returned for analysis.26 dressing pouches were returned.1 contained a folded dressing as described in the complaint.1 pouch was open and had the number 1 backing paper present only and 3 pouches were open and empty.The other remaining dressings were as expected and functioned as intended.Due to the folded dressing being present we have been able to confirm a relationship between the event and the device.The batch records were reviewed and it could be confirmed that the products had progressed through a satisfactory release process which involved testing the product against the requirements of the finished product specification.There was also no issue identified during the manufacturing process that could have caused or contributed to the complaint problem.A complaint history review revealed no similar instances in the last three years.A risk management review concluded that the sequence of events described in this complaint are not contained in the relevant risk files.There is insufficient information within the complaint description and further information included in this complaint to provide a causal link between events and the product therefore no update to the risk files is warranted.As the event was described as happening during use even though external to patient, the most probable root cause is that the backing papers have not been removed in accordance with the ifu.If not removed in the right order the device can unfold and stick to itself as described in this case.The users of the reported product are advised to consult the ifu, to prevent future occurrences of the reported issue.This guide provides comprehensive instructions of the operation, use and limitations of the device.This investigation is now complete, with no corrective actions required.No further actions by smith and nephew are deemed necessary at this stage.However, we will continue to monitor for any adverse trends relating to this product range.Smith and nephew acknowledge customer concern and are continually investigating ways to develop and improve our products.Internal complaint reference number: case-2022-00092379-1.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IV3000 1 HAND 6X7CM CTN 100
Common Device Name
TAPE AND BANDAGE, ADHESIVE
Manufacturer (Section D)
SMITH & NEPHEW MEDICAL LTD.
101 hessle road
hull east riding of yorkshire HU3 2 BN
UK  HU3 2BN
Manufacturer (Section G)
SMITH & NEPHEW MEDICAL LTD.
101 hessle road
hull east riding of yorkshire HU3 2 BN
UK   HU3 2BN
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key13664255
Report Number8043484-2022-00089
Device Sequence Number20202353
Product Code KGX
UDI-Device Identifier05000223417383
UDI-Public05000223417383
Combination Product (Y/N)N
Initial Reporter CountryCH
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 05/12/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/01/2023
Device Model Number66024007
Device Catalogue Number4007
Device Lot Number2018
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/14/2022
Supplement Date Received by Manufacturer05/11/2022
Initial Report FDA Received Date03/03/2022
Supplement Report FDA Received Date05/12/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured04/27/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-