SMITH & NEPHEW, INC. GNS II CMT TIB SIZE 3 LEFT; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL Back to Search Results
Model Number 71420164
Medical Device Problem Code Positioning Failure (1158)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/11/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that, during a tka surgery, three gii dished ins sz 3-4 9mm and one gii c/r art ins sz 3-4 9mm could not be inserted far enough into the dovetail guide and be finally fixed in the already implanted gns ii cmt tib size 3 left (lot no.H2136412).A fifth attempt was made with a lgn xlpe dished isrt sz 3-4 9mm, which could be fixed in the tibia by using an additional hammer blows and force.A significant delay occurred as a consequence of these issues.No other complications were reported.
 
Additional Manufacturer Narrative
(b)(4).
 
Additional Manufacturer Narrative
Section h10: this complaint reports five attempts performed by a surgeon to position five different inserts.The positioning was successful after the fifth attempt.Four inserts were returned for evaluation.Considering that the base plate is implanted into the patient¿s anatomy, and a visual inspection of the returned mating inserts confirmed to be damaged from the attempted insertions, it was not possible to evaluate the interaction between the returned product and the implanted base plate.Nevertheless, based on the testimonial evidence, the contribution of the product to the event was corroborated.Even though over the previous 12 months, similar events were identified for the reported inserts, no similar events were identified for the specific batches.And a review of complaint history over the past 12 months for the reported tibial baseplate part number and the specific batch number did not reveal any similar events.In addition, a review of the manufacturing records for all devices involved, inserts and tibial base plate, did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.At this time, we do not have reason to suspect that the product failed to meet any product specifications at the time of manufacture.A review of the risk management files revealed that this failure mode was previously identified.The anticipated risk level is still adequate.Assessment of historical escalated cases concluded that there are no prior actions related to these devices and failure mode.Possible causes could include but are not limited to insertion technique or procedural variance.Based on this investigation, the need for corrective action is not indicated.Should additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor future complaints and investigate as necessary.Internal complaint reference number: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GNS II CMT TIB SIZE 3 LEFT
Common Device Name
PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
Manufacturer (Section G)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key13664303
Report Number1020279-2022-01013
Device Sequence Number4659206
Product Code JWH
UDI-Device Identifier03596010206251
UDI-Public03596010206251
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K951987
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 09/08/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number71420164
Device Catalogue Number71420164
Device Lot NumberH2136412
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/14/2022
Supplement Date Received by Manufacturer08/19/2022
Initial Report FDA Received Date03/03/2022
Supplement Report FDA Received Date09/08/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured07/27/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-