Model Number MZ9273
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/19/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device expiration date: unknown fda notified: the initial reporter also notified the fda via medwatch uf/importer report #: (b)(4).A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.Device manufacture date: unknown.
 
Event or Problem Description
It was reported that the bd maxzero multi-fuse extension set with needleless connector(s) experienced leakage.The following information was provided by the initial reporter: ivf leaking at tpn filter.
 
Additional Manufacturer Narrative
The following fields were updated due to additional information: d9: device available for eval yes, d9: returned to manufacturer on: 11-jul-2022.H6: investigation summary: samples were received and tested by our quality team.The sets presented with leaks in filters just like the customer described- this verified the complaint.The cause for these leaks is unknown but our manufacturing and r&d teams are aware of this and diligently working to solve the issue of filter leaks.The sets and filters were then sent to the filter manufacturer in italy where they were washed to remove any biological material or substance left from clinical use.Once the filters and their respective membranes were cleaned completely, the supplier reported no leakage or issues with the sets whatsoever.The filters were tested using pressurized infusion and forced leaks were only noticed at pressures high above any that would be used in clinical setting.Visual analyses under microscope also confirmed that there were no abnormalities in any of these filters or sets.This failure remains an unknown root cause but our engineers and researchers are working diligently to eliminate reoccurrence.A device history record review could not be performed because a lot number was not provided by the customer.H3 other text : see h10.
 
Event or Problem Description
It was reported that the bd maxzero multi-fuse extension set with needleless connector(s) experienced leakage.The following information was provided by the initial reporter: ivf leaking at tpn filter.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MAXZERO MULTI-FUSE EXTENSION SET WITH NEEDLELESS CONNECTOR(S)
Common Device Name
INTRAVASCULAR ADMINISTRATION SET
Manufacturer (Section D)
SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer (Section G)
SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key13670490
Report Number9616066-2022-00202
Device Sequence Number5466573
Product Code FPA
UDI-Device Identifier50885403240858
UDI-Public50885403240858
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
PMA/510(K) Number
K140831
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 07/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Model NumberMZ9273
Device Catalogue NumberMZ9273
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/22/2022
Supplement Date Received by Manufacturer07/22/2022
Initial Report FDA Received Date03/04/2022
Supplement Report FDA Received Date08/11/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-