MEDOS INTERNATIONAL SARL GALAXY G3 MINI 2.5MM X 4.5CM; NEUROVASCULAR EMBOLIZATION DEVICE Back to Search Results
Model Number GLM925045
Medical Device Problem Code Device Difficult to Setup or Prepare (1487)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/10/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Product complaint # (b)(4).The purpose of this mdr submission is to report the findings of the device investigation.The embolic coil was stretched, meeting regulatory reporting criteria.Information regarding patient weight, height, medical history, race, and ethnicity was not reported.Procode: krd/hcg.Initial reporter: the customer contact information, including name, occupation, phone, fax, and e-mail address, was not reported.Missing information from this report is identified as blank; this information was not provided in the reported event or available at the time of report submission.A supplemental report will be submitted if new facts arise which materially alter information submitted in a previous mdr report.Complaint conclusion: as reported by the field, during the resheathing of a 2.5mm x 4.5cm galaxy g3 mini coil (glm925045, 30383054) the coil the introducer failed to be re-zipped.There was no patient injury reported.A non-sterile galaxy g3 mini 2.5mm x 4.5cm was received inside of a pouch.It was noted the core wire was observed in good conditions with the coil still attached.The introducer was not returned to analysis.The embolic coil was observed stretched.No further test could be performed due to the conditions above noted.The functional test could not be performed due to the damage observed at the embolic coil.A manufacturing record evaluation (mre) was performed for the finished device 30383054 number, and no non-conformances related to the reported complaint condition were identified the device was returned to cerenovus for further evaluation.Upon arrival, the core wire was observed in good conditions with the coil still attached.The introducer was not returned to analysis.Under microscopic magnification, the embolic coil was observed severely stretched.Due to this condition, the functional test could not be performed.However, it cannot be determined if this damage was secondary or a contributing factor to the failure mode since the introducer did not return for analysis.The customer complaint could not be confirmed, the event description and device analysis do not provide clear insight into the root cause and/or exact contributing factors that may have resulted in the observed failure mode.Assignment of root cause for the event remains speculative and inconclusive, based on the limited information provided and the evidence presented by the returned device; however, it is possible that clinical and procedural factors, including device manipulation and device interaction, may have contributed to the reported failures and damages on the returned system.Multiple attempts to obtain additional information were unsuccessful.If information is provided at a later date, the file will be reopened and processed accordingly.As part of the cerenovus quality process, all devices are manufactured, inspected, and released to approved specifications.As part of the post market surveillance program, information from this complaint is trended to identify statistical signals for consideration of further correction action.Since there was no evidence to suggest the event was related to a manufacturing or design issue, no corrective actions will be taken at this time.
 
Event or Problem Description
As reported by the field, during the resheathing of a 2.5mm x 4.5cm galaxy g3 mini coil ( glm925045, 30383054) the coil the introducer failed to be re-zipped.There was no patient injury reported.Based on the analysis of the device received, the embolic coil was observed stretched.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GALAXY G3 MINI 2.5MM X 4.5CM
Common Device Name
NEUROVASCULAR EMBOLIZATION DEVICE
Manufacturer (Section D)
MEDOS INTERNATIONAL SARL
chemin-blanc 38
le locle neuchatel CH-24 00
SZ  CH-2400
Manufacturer (Section G)
CODMAN & SHURTLEFF, INC. (FREMONT)
47709 fremont blvd
fremont CA 94538
Manufacturer Contact
gabriel alfageme
31 technology dr
irvine, CA 92618
9497898687
MDR Report Key13685018
Report Number3008114965-2022-00169
Device Sequence Number17435793
Product Code KRD
UDI-Device Identifier10886704080275
UDI-Public10886704080275
Combination Product (Y/N)N
PMA/510(K) Number
K171862
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 03/07/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/31/2023
Device Model NumberGLM925045
Device Catalogue NumberGLM925045
Device Lot Number30383054
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/22/2022
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/04/2022
Initial Report FDA Received Date03/07/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/13/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1