Model Number 801-36545M
Medical Device Problem Code Migration (4003)
Health Effect - Clinical Codes Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/26/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that a mesa uniplanar screw experienced axial slippage post-operatively.This led to loss of correction in the patient.It is not known at this time if revision surgery is scheduled or will be performed.
 
Additional Manufacturer Narrative
Visual, dimensional, material and functional analysis could not be performed as the device was not returned.Post op x rays were provided.The x ray did not show the full construct, just the end of the construct.It cannot be determined if a slip occurred from the provided x rays as the x rays are at different angles.The construct does not appear to go thru the curve of the deformity and every other level is fixated alternatively.Device history records could not be reviewed as a valid lot number was not provided and could not be obtained.Complaint history records for this catalog number, similar complaints from the same surgeon were identified.Similar construct design x rays from the same surgeon for the same failure mode were provided and reviewed by a consultant spine hcp.The hcp believes construct design with difficult deformities was the most likely contributing factor to the event.From his analysis, the surgeon used a low density screw construct ending the construct on the convex curve of the deformity.The low screw density, short length of construct along with possible loss of correction may not have been enough to counter the force of the spine trying to revert to it's original position, causing a failure at the construct's weakest point, the distal most screw on the convex of the deformity curve, leading to the rod slipping from the screw.It is also unknown how long these device's were implanted as the ifu states "internal fixation devices are load sharing devices which maintain alignment until healing occurs.If healing is delayed or does not occur the implant could eventually break, bend or loosen.Loads produced by load bearing and activity levels will impact the longevity of the implant." length of implantation may have contributed to the event.
 
Event or Problem Description
It was reported that a mesa uniplanar screw experienced axial slippage post-operatively.This led to loss of correction in the patient.It is not known at this time if revision surgery is scheduled or will be performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DEFORMITY, UNIPLANAR SCREW; SIZE Ø6.5X45 MM
Common Device Name
THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM
Manufacturer (Section D)
K2M, INC.
600 hope parkway se
leesburg VA 20175
Manufacturer (Section G)
K2M, INC.
600 hope parkway se
leesburg VA 20175
Manufacturer Contact
rita karan
2 pearl court
allendale, NJ 07401
2017608000
MDR Report Key13690274
Report Number3004774118-2022-00090
Device Sequence Number1943425
Product Code NKB
UDI-Device Identifier10888857140301
UDI-Public10888857140301
Combination Product (Y/N)N
Initial Reporter CountryNL
PMA/510(K) Number
K141873
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 06/23/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number801-36545M
Device Catalogue Number801-36545M
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/24/2022
Supplement Date Received by Manufacturer06/03/2022
Initial Report FDA Received Date03/08/2022
Supplement Report FDA Received Date06/23/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-