No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.This emdr represents the bard/davol sepramesh ip.An additional emdr was submitted to represent the bard/davol ventralight st mesh.Should additional information be provided, a supplemental emdr will be submitted.
|
|
Attorney alleges that the patient underwent surgery for implant of unspecified bard/davol sepramesh ip, ventralight st and ventrio st on (b)(6) 2014 and/or (b)(6) 2015 and/or (b)(6) 2016.As reported, the patient is making a claim for an adverse patient outcome against the sepramesh ip and ventralight st.Attorney alleges that the patient had subsequent surgical intervention due to the hernia mesh device.It is also alleged that the patient experienced emotional distress and the device was defective.
|
|
Attorney alleges that the patient underwent surgery for implant of unspecified bard/davol sepramesh ip, ventralight st and ventrio st on (b)(6) 2014 and/or (b)(6) 2015 and/or (b)(6) 2016.As reported, the patient is making a claim for an adverse patient outcome against the sepramesh ip and ventralight st.Attorney alleges that the patient had subsequent surgical intervention due to the hernia mesh device.It is also alleged that the patient experienced emotional distress and the device was defective.Addendum per additional information provided: (b)(6) 2014 ¿ patient was diagnosed with recurrent ventral incisional hernia thereby underwent laparoscopic repair with ventralight st using echo ps (device 1).Per operative notes, ¿the adhesions inside the hernia sac was reduced and sutured.A ventralight st using echo ps (device 1) was placed over the peritoneal cavity covering the hernia defect and sutured.¿ (b)(6) 2015 ¿ patient was diagnosed with recurrent incisional hernia thereby underwent open repair with implant of sepramesh ip (device 2).Per operative notes, ¿the incisional hernia with sac was incised and adhesions of greater ometum were lysed.A sepramesh ip (device 2) was placed over the defect and sutured in place.¿ (b)(6) 2016 ¿ patient was diagnosed with recurrent incisional hernia thereby underwent laparoscopic repair with implant of ventrio st (device 3).Per operative notes, ¿adhesions between abdominal wall and hernia sac was removed.The ventrio st (device 3) mesh was placed into the peritoneal cavity covering the defect.Multiple small defects in the anterior abdominal wall was closed with sutures and tacks.¿.
|
|
No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Addendum: this supplemental emdr is submitted to document additional information provided.Root cause is inconclusive, no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-jul-2014) is considered to be a best estimate.Updated fields: a2, b3, b4, b5, b7, d3, d4 (product catalog no., corporate lot no., udi no., expiry date), d6a, g3, g6, h2, h4, h6, h10.This supplemental emdr represents the bard/davol sepramesh ip (device 1).An additional emdr was submitted to represent the bard/davol ventralight st using echo ps (device 2).Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|