IRIDEX CORPORATION MICROPULSE P3; LASER INSTRUMENT, SURGICAL, POWERED, PRODUCT CODE: HQF
|
Back to Search Results |
|
| Model Number |
15522 |
| Health Effect - Clinical Code |
Eye Burn (2523)
|
| Date of Event |
02/09/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Iridex became aware of a complaint on (b)(6), 2022 reporting a patient experiencing conjunctival burn on (b)(6) 2021 during treatment with the micropulse p3 probe.This complaint was reported to iridex approximately 2.5 months after the incident occurred.Based on the information provided, it appears the treatment was performed within specifications.A definitive root cause could not be determined and no additional information has been provided by the clinic or treating physician.Based on similar reported events, the most likely cause of the issue is suspected to be contamination (e.G.Blood, tissue or betadine) on the probe tip when the laser was activated or laser activation when the probe is over pigmented conjunctival tissue.Engineering failure analysis could not be performed because the device was not returned for evaluation.The results of post market data review indicate that this failure mode is not occurring with greater severity or frequency based on the number of events reported evaluated against the number of cases performed.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is provided to update the following: 1)part b: b5 -product problem section was updated.2) report c: is this a combination product - no.3) report d: updates to section d8, d9, d4.4) part h: update to include that this a correction and additional information report.5) part d: updated this section with the udi number.6) part e: updates to the initial reporter section with information regarding the complainant.Note: patient information was not provided, therefore part a is not filled out.
|
| |
|
Event or Problem Description
|
|
Iridex became aware of a complaint on 9th february, 2022 reporting a patient experiencing conjunctival burn on (b)(6) 2021 during treatment with the micropulse p3 probe.This complaint was reported to iridex approximately 2.5 months after the incident occurred.Based on the information provided, it appears the treatment was performed within specifications.Based on similar reported events, the most likely cause of the issue is suspected to be contamination (e.G.Blood, tissue or betadine) on the probe tip when the laser was activated or laser activation when the probe is over pigmented conjunctival tissue.Based on the information provided by the complainant, the most likely cause of the burn was determined to be use of the device after the device tip was contaminated with blood.The micropulse p3 ifu contains instructions for inspecting and cleaning the device tip during use, and the ifu contains the warning that "contamination of the device tip with blood or tissue of the fiber optic by blood or tissue char can result in surface burns in the eye.".
|
| |
|
Search Alerts/Recalls
|
|
|