• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION SYMMETRY; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION SYMMETRY; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL Back to Search Results
Model Number 23295
Medical Device Problem Codes Inflation Problem (1310); Material Rupture (1546)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/18/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Age at time of event: 18 years or older.(b)(6).
 
Event or Problem Description
It was reported that balloon rupture occurred.The 50% stenosed target lesion was located in a shunt in a moderately tortuous and non-calcified vessel in the left hand.A 5.0-4/4t/90 symmetry balloon catheter was advanced for dilation.However, during inflation, the pressure did not rise at all and the usage was stopped.Upon pulling out the device and verified, there was a possibility of a balloon rupture.The procedure was successfully completed with a different device.No patient complications nor injuries were reported.
 
Event or Problem Description
It was reported that balloon rupture occurred.The 50% stenosed target lesion was located in a shunt in a moderately tortuous and non-calcified vessel in the left hand.A 5.0-4/4t/90 symmetry balloon catheter was advanced for dilation.However, during inflation, the pressure did not rise at all and the usage was stopped.Upon pulling out the device and verified, there was a possibility of a balloon rupture.The procedure was successfully completed with a different device.No patient complications nor injuries were reported.
 
Additional Manufacturer Narrative
(a2) age at time of event: 18 years or older.(e1) initial reporter city: (b)(6).Device evaluated by mfr.: a symmetry device was received for analysis.A visual examination identified that the balloon was not folded which indicates that the device was subjected to positive pressure.The returned device was attached to a boston scientific encore inflation unit and positive pressure was applied; the balloon was inflated to its rate of burst pressure of 15 atmospheres.A pinhole leak on the surface of the distal balloon bond was identified.A visual examination found no issue with the markerbands.A visual and tactile examination found that the shaft was free from damage.No issues were noted which may have potentially contributed to the complaint incident.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYMMETRY
Common Device Name
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI  
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key13733304
Report Number2134265-2022-02298
Device Sequence Number5008887
Product Code LIT
UDI-Device Identifier08714729181897
UDI-Public08714729181897
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K143193
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/27/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/17/2024
Device Model Number23295
Device Catalogue Number23295
Device Lot Number0027860629
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/18/2022
Supplement Date Received by Manufacturer04/05/2022
Initial Report FDA Received Date03/11/2022
Supplement Report FDA Received Date04/27/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/18/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexFemale
-
-