Model Number 85020
Medical Device Problem Code Failure to Deliver Energy (1211)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/29/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device was returned for analysis to boston scientific.Per visual inspection the device presents a bent/kink in the proximal part of the tip.Also, there is a cut in the distal part of the catheter shaft.Functional test showed that the steering knob and the tension control knob functioned properly on both lock and unlock positions.No abnormal resistance was felt when actuating the steering mechanism.There is an open in the tip and second ring after continuity test finding.Per dissection test the cut in the catheter shaft was confirmed affecting the tip and the ring 2.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.
 
Event or Problem Description
Reportable based on device analysis completed on 24feb2022.It was reported that during a cardiac radiofrequency ablation procedure, a blazer ii catheter had poor contact and could not discharge.There were no issues regarding temperature.The catheter was discharged intermittently and could not be used normally.No error messages.Temperature control mode was in use.Procedure was completed with another of same device.No patient injury reported.Device was returned to boston scientific for analysis.However, device analysis revealed that there is a cut in the distal part of the catheter shaft.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BLAZER II
Common Device Name
CARDIAC ABLATION PERCUTANEOUS CATHETER
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
302 parkway, global park
la aurora - heredia
CS  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
dc a330
saint paul, MN 55112
6515826168
MDR Report Key13805346
Report Number2134265-2022-03075
Device Sequence Number12027728
Product Code LPB
UDI-Device Identifier08714729199939
UDI-Public08714729199939
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
P920047
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 03/17/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/11/2024
Device Model Number85020
Device Catalogue Number85020
Device Lot Number0026795644
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/15/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/24/2022
Initial Report FDA Received Date03/18/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/11/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient Age20 YR
Patient SexMale
Patient Weight70 KG
-
-