• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY SYNCHRO SELECT-14 SOFT PS 215CM; WIRE, GUIDE, CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY SYNCHRO SELECT-14 SOFT PS 215CM; WIRE, GUIDE, CATHETER Back to Search Results
Model Number SSFT215PRE
Medical Device Problem Code Peeled/Delaminated (1454)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/18/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported after the procedure was completed the guidewire (subject device) coating was peeling in the middle.The procedure was completed successfully with no clinical consequences to the patient.
 
Event or Problem Description
It was reported after the procedure was completed the guidewire (subject device) coating was peeling in the middle.The procedure was completed successfully with no clinical consequences to the patient.
 
Additional Manufacturer Narrative
There are controls in the manufacturing process to ensure the product met specifications upon release.The lhr (lot history record) for each lot is created and maintained according to the qs (quality system).Controls within the qs ensure that all product is manufactured in accordance to the dmr (device master record).The device was returned and the lot number was not confirmed as the packaging was not returned with the device.During visual inspection it was seen an attempt had been made to shape the guidewire tip.The guidewire was noted to be kinked/bent at 53cm and 204cm from the proximal end.The guidewire ptfe coating was noted to be peeling in multiple areas to 93.5cm from the proximal end.The core wire distal end was observed through the distal tip dome.The guidewire was returned with ptfe peelings wrapped in medical gauze.Ptfe peeling was noted in the distal end of the returned introducer.Hydrophilic coating was hydrated there were no anomalies noted.Functional testing was not performed.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.The event was confirmed based on the damage noted to the returned device.The device failed to meet specification when returned for analysis.Additional information indicates there was no damage noted to the packaging prior to opening the packaging, the device was confirmed to be in good condition during preparation/prior to use on the patient, the device was prepared for use as per the directions for use, continuous flush was set up and maintained throughout the clinical procedure.There was no resistance when the guidewire was taken out of the dispenser hoop.The guidewire was not shaped.Flush was not given inside the microcatheter at the time when the guidewire was inserted.There was no friction or resistance felt at the hub.The introducer sheath was used, when inserting the guidewire.It is unknown which part of the coating peeled off.The patient¿s anatomy was normal tortuous.Analysis of the returned device found the peeling/scraping is consistent with backloading the proximal end of the guidewire into the distal end of the introducer and pulling it through the introducer.The as reported and as analyzed event of the guidewire ptfe coating peeling in addition to the as analyzed event of the guidewire kinked/bent will be assigned handling damage as the issue is due to handling of the product or portion of the product during the clinical procedure, upon removal of the product from the packaging, or preparation of the product prior to use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNCHRO SELECT-14 SOFT PS 215CM
Common Device Name
WIRE, GUIDE, CATHETER
Manufacturer (Section D)
STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY
4870 west 2100 south
salt lake city UT 84120
Manufacturer (Section G)
STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY
4870 west 2100 south
salt lake city UT 84120
Manufacturer Contact
tara lopez
47900 bayside parkway
fremont, CA 94538
5104132500
MDR Report Key13827129
Report Number3012931345-2022-00050
Device Sequence Number17259920
Product Code MOF
UDI-Device Identifier07613327508598
UDI-Public07613327508598
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K202522
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 06/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/15/2023
Device Model NumberSSFT215PRE
Device Catalogue NumberSSFT215PRE
Device Lot Number23109899
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/07/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/20/2022
Supplement Date Received by Manufacturer05/31/2022
Initial Report FDA Received Date03/19/2022
Supplement Report FDA Received Date06/22/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/16/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SL -10 MICROCATHETER (STRYKER)
Patient SexUnknown
-
-