MAUDE Adverse Event Report: ARTHREX, INC. AR-400UB UNSTERILE BATTERY; INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. AR-400UB UNSTERILE BATTERY; INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT Back to Search Results
Model Number AR-400UB UNSTERILE BATTERY
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 02/28/2022
Type of Reportable Event Malfunction
Event or Problem Description
On 02/28/2022, it was reported by a sales representative via sems that an ar-400ubc battery charger and ar-400ub battery caught on fire and melted the console.Requested additional information.
 
Additional Manufacturer Narrative
The contribution of the device to the reported event could not be determined as the device was not returned for evaluation.The root cause of the event could not be determined from the information available and without device evaluation.If the device becomes available for evaluation, a follow-up report will be submitted.
 
Additional Manufacturer Narrative
Confirmed.The thermal event has caused significant damage to the pcb and it¿s components, root cause can¿t be determined.From the data it appears that the fuse may not have opened properly.This failure caused the pcba temperature to rise, centered on the fuse, due to the wattage driven through the heater element of the fuse to activate it.The temperature of the pcb at the fuse continued to increase until the temperature exceeded the pcb material 150°c tg, causing it to break down.With the fuse located above cell 3, cell 3 overheated.The vent on the cell opened once the temperature increased the internal cell pressure above its threshold.From the teardown of cell 3, the cell was not shorted and did not go into thermal runaway.Eventually, the pcb melted and shorted multiple conductors contributing to the pcb heating.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AR-400UB UNSTERILE BATTERY
Common Device Name
INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
vik bajnath
8009337001
MDR Report Key13839510
Report Number1220246-2022-04616
Device Sequence Number5812794
Product Code HWE
UDI-Device Identifier00888867223332
UDI-Public00888867223332
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 09/09/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberAR-400UB UNSTERILE BATTERY
Device Catalogue NumberAR-400UB
Device Lot NumberGB6318581
Was Device Available for Evaluation? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/28/2022
Supplement Date Received by Manufacturer02/28/2022
Initial Report FDA Received Date03/21/2022
Supplement Report FDA Received Date09/09/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured03/26/2021
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-