BECTON DICKINSON MEDICAL (SINGAPORE) BD LUER-LOK¿ SYRINGE WITH DETACHABLE BD ECLIPSE¿ NEEDLE; HYPODERMIC SINGLE LUMEN NEEDLE Back to Search Results
Model Number 305782
Medical Device Problem Code Defective Component (2292)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/03/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
There were multiple pma / 510(k)#s reported to be involved.The information for each 510(k) number is as follows: pma / 510(k)#: k980987 (syringe).Pma / 510(k)#: k161170 (needle).A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that the stopper was misaligned in the bd luer-lok¿ syringe with detachable bd eclipse¿ needle.The following information was provided by the initial reporter: "distorted stopper.".
 
Event or Problem Description
It was reported that the stopper was misaligned in the bd luer-lok¿ syringe with detachable bd eclipse¿ needle.The following information was provided by the initial reporter: "distorted stopper.
 
Additional Manufacturer Narrative
The following fields were updated due to additional information: d.9.Device available for eval?: yes.D.9.Returned to manufacturer on: 14-mar-2022.H.6.Investigation: one photo and one sample were received by our quality team for evaluation.From the photo, stopper mis-assembly was observed.The syringe sample was subjected to visual inspection and also observed stopper mis-assembly.In addition, upon removal of the plunger from the stopper, short molding at the plunger head was observed.A review of the internal manufacturing device records and raw material history files for the reported lot number was performed and no recorded quality problems or rejections to this incident were found.In the syringe assembly process, there is a vision system at the 3 ml line to check for product with stopper mis-assembly and be auto-rejected at the reject station.The vision system is also challenged every shift with accordance to the assembly process daily checklist.The vision system was challenged and able to reject product with stopper mis-assembly.Therefore, the stopper mis-assembly could be due to short molding at the plunger head resulting in the stopper not properly being inserted to the plunger.Short molding on the plunger head could have occurred during machine start-up.The initial shots with a short molding defect after machine start-up were not effectively purged and removed before being conveyed to the subsequent process.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD LUER-LOK¿ SYRINGE WITH DETACHABLE BD ECLIPSE¿ NEEDLE
Common Device Name
HYPODERMIC SINGLE LUMEN NEEDLE
Manufacturer (Section D)
BECTON DICKINSON MEDICAL (SINGAPORE)
30 tuas avenue 2
singapore
Manufacturer (Section G)
BECTON DICKINSON MEDICAL (SINGAPORE)
30 tuas avenue 2
singapore
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key13869885
Report Number8041187-2022-00144
Device Sequence Number17460827
Product Code FMI
UDI-Device Identifier30382903057826
UDI-Public30382903057826
Combination Product (Y/N)N
Initial Reporter CountryTW
PMA/510(K) Number
SEE H10
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 04/05/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date10/31/2025
Device Model Number305782
Device Catalogue Number305782
Device Lot Number0300497
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/03/2022
Supplement Date Received by Manufacturer04/05/2022
Initial Report FDA Received Date03/23/2022
Supplement Report FDA Received Date04/22/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/26/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-