| Model Number |
33103 |
| Medical Device Problem Code |
Nonstandard Device (1420)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/28/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that the customer was trying out male external catheters and have tried two types but both were inconsistently staying in place through the night.Customer mentioned that they have stayed on 2 out of 5 nights (lot: jufv2649 & lot: jufx2803).Inquirer reviewed the direction for use with the customer and found that they were appropriately applying the catheter.Customer reported that they cleaned the penis with soap and water, thoroughly dried it and applied the catheter so that it had a limited number of wrinkles and tried to squeeze it so that the adhesive stuck to the skin.Customer also reported that the larger of the two catheters seemed to fit the patient better but said that it even came off and also noted that some catheters seemed to be more sticky than others (lot: jufv2649 & lot: jufx2803).
|
| |
|
Additional Manufacturer Narrative
|
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The device was not returned.
|
| |
|
Event or Problem Description
|
|
It was reported that the customer was trying out male external catheters and have tried two types but both were inconsistently staying in place through the night.Customer mentioned that they have stayed on 2 out of 5 nights (lot: jufv2649 & lot: jufx2803).Inquirer reviewed the direction for use with the customer and found that they were appropriately applying the catheter.Customer reported that they cleaned the penis with soap and water, thoroughly dried it and applied the catheter so that it had a limited number of wrinkles and tried to squeeze it so that the adhesive stuck to the skin.Customer also reported that the larger of the two catheters seemed to fit the patient better but said that it even came off and also noted that some catheters seemed to be more sticky than others (lot: jufv2649 & lot: jufx2803).
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event was inconclusive because no sample was returned.A potential root cause for this failure could be "operator error".The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: ''contraindication do not use on irritated or compromised skin.Precaution do not use if allergic reaction occurs.For good hygiene, change catheter daily.Use of a single device for longer periods than 24 hours may increase the risk of complications.Directions: to apply 1) wash penis with mild soap and warmwater.Dry thoroughly.2) trim pubic hair if necessary.3) unroll self-adhering catheter over penis.4) gently squeeze the catheter to properly seal adhesive to the skin.Important: wear time may be significantly reduced if adhesive is not properly sealed to the skin.5) connect to drainage device.Directions: to remove gently roll catheter off the penis.Note: if necessary, apply a warm wet compress (such as a wet washcloth) around the catheter to help loosen the adhesive." the device was not returned.
|
| |
|