Model Number 18006236
Medical Device Problem Code Migration (4003)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/28/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the patient underwent an initial three (3) level anterior cervical plate fixation procedure.Subsequently, a post-operative evaluation performed sixteen (16) months later identified both screws at the bottom level appeared to be backing out.There is no intent to revise the construct at this time.No further patient impact was reported.
 
Additional Manufacturer Narrative
The reported event was confirmed by review of the radiographic image provided.No product was returned to nuvasive for evaluation as the device remains in-situ.Further, operative notes and/or immediate post-op radiographs were not provided for review of usage/technique to determine if the screws were adequately seated and the construct was appropriately locked during the initial procedure.A definitive root cause was unable to be determined with the information provided.There are warnings in the device labeling that this type of event can occur: ".Potential adverse events and complications: potential risks identified with the use of this system, which may require additional surgery, include: bending, fracture or loosening of implant component(s)." ".Warnings, cautions and precautions: to allow for proper utility of the locking mechanism during screw placement, use a drill-guide with the awl and/or drill to create a centered screw hole into the vertebral bodies.Care should be taken to ensure that all components are ideally fixated prior to closure." ".Post-operative warnings: during the postoperative phase it is of particular importance that the physician keeps the patient well informed of all procedures and treatments.Damage to the weight-bearing structures can give rise to loosening of the components, dislocation and migration, as well as to other complications.To ensure the earliest possible detection of such catalysts of device dysfunction, the devices must be checked periodically postoperatively, using appropriate radiographic techniques." if any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional information received subsequent to the initial medwatch submission.
 
Event or Problem Description
It was reported that the patient underwent an initial two (2) level anterior cervical plate fixation procedure.Subsequently, a post-operative evaluation performed approximately six (6) weeks later identified both screws at the bottom level appeared to be backing out.There is no intent to revise the construct at this time.No further patient impact was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NUVASIVE ACP HYBRID PLATE SYSTEM
Common Device Name
APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY
Manufacturer (Section D)
NUVASIVE, INC.
7475 lusk boulevard
san diego CA 92121
Manufacturer (Section G)
NUVASIVE, INC.
7475 lusk boulevard
san diego CA 92121
Manufacturer Contact
geoff gannon
7475 lusk boulevard
san diego, CA 92121
MDR Report Key13896312
Report Number2031966-2022-00064
Device Sequence Number19804205
Product Code KWQ
UDI-Device Identifier00195377009784
UDI-Public195377009784
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K201078
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 03/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number18006236
Device Catalogue NumberN/A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/28/2022
Supplement Date Received by Manufacturer03/25/2022
Initial Report FDA Received Date03/24/2022
Supplement Report FDA Received Date03/29/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ACP SCREW, 3.5X15MM (QTY (B)(4)); ACP SCREW, 3.5X19MM (QTY (B)(4))
Patient SexPrefer Not To Disclose
-
-