Model Number 43303
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/07/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
An investigation is currently underway.Upon completion, the results will be forwarded.
 
Event or Problem Description
The customer reported that after changing the end cap, fluid was noted to be spraying out of the picc line.There was no leaking noted during fluid administration or fluid in the bed.The picc line was quickly discontinued and an additional piv was placed.There was no patient harm.
 
Additional Manufacturer Narrative
One used catheter from lot number 1913500227 was received at the manufacturing site inside of a generic plastic bag for evaluation.A visual inspection revealed that the sample was received with a syringe, adapter, and additional stabilizing wing, all of which do not belong to the cardinal health device.A physical evaluation was performed and revealed both bubbles and a hole just below the strain relief.The device history record (dhr) was reviewed and revealed no discrepancies that may have contributed to a complaint of this failure mode.All quality assurance testing performed during manufacturing was acceptable.The quality assurance review of the visual, physical, and dimensional evaluation results indicated that the product met specification requirements.In addition, all dhrs are reviewed for accuracy prior to product release.The manufacturing process was reviewed, and a cause-and-effect diagram was utilized to identify any possible root causes.No manufacturing related root causes were identified.Based on all available information, the device was in good condition prior to use and there was no indication that the device was leaking during recommended flushing, therefore the most probable root cause is user misuse as leaking was only noted after the cap was changed.It must be noted that in-process controls (such as personnel training, incoming quality acceptance testing for raw material, 100% in process visual inspection and visual acceptance sampling are performed in the plant) are in place to prevent nonconforming product from leaving the manufacturing operations.This complaint will be used for tracking and trending purposes.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
1.9F ARGYLE SINGLE LUMEN PICC
Common Device Name
CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
Manufacturer (Section D)
CARDINAL HEALTH
edificio b20 calle #2 zona fra
alajuela
CS 
Manufacturer (Section G)
CARDINAL HEALTH
edificio b20 calle #2 zona fra
alajuela
CS  
Manufacturer Contact
jill saraiva
777 west street
mansfield, MA 02048
5086183640
MDR Report Key13896501
Report Number3009211636-2022-00779
Device Sequence Number4391369
Product Code LJS
UDI-Device Identifier10884527004645
UDI-Public10884527004645
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 04/20/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model Number43303
Device Catalogue Number43303
Device Lot Number1913500227
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 03/14/2022
Supplement Date Received by Manufacturer03/14/2022
Initial Report FDA Received Date03/24/2022
Supplement Report FDA Received Date04/20/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured05/21/2019
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device A
Patient Sequence Number1
Patient SexUnknown
-
-