• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: FX SOLUTIONS HUMELOCK REVERSED; REVERSED SHOULDER PROSTHESIS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

FX SOLUTIONS HUMELOCK REVERSED; REVERSED SHOULDER PROSTHESIS Back to Search Results
Model Number 105-0024
Health Effect - Clinical Code Unspecified Infection (1930)
Date of Event 09/17/2021
Type of Reportable Event Serious Injury
Event or Problem Description
The patient was revised on (b)(6) 2021 for infection.Approximately 1 month after the first surgery.The surgeon explanted 3 standard screw (4.5/25mm, 4.5/40mm and 4.5/30mm), 2 locking screw (4.5/40mm and 4.5/20mm), 1 humeral cup (40/6), 1 glenoid baseplate (24mm), 1 centered glenosphere (40/10) and 1 humelock reversed stem cementless (40/14).
 
Additional Manufacturer Narrative
This mdr has already been submitted to fda by the us importer with report number (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HUMELOCK REVERSED
Common Device Name
REVERSED SHOULDER PROSTHESIS
Manufacturer (Section D)
FX SOLUTIONS
1663 rue des majornas
viriat, 01440
FR  01440
Manufacturer (Section G)
FX SOLUTIONS
1663 rue des majornas
viriat, 01440
FR   01440
Manufacturer Contact
ratsamy thevenin
1663 rue des majornas
viriat, 01440
FR   01440
MDR Report Key13898731
Report Number3009532798-2022-00005
Device Sequence Number4065147
Product Code PHX
UDI-Device Identifier03701037300237
UDI-Public03701037300237
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K150488
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2021
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 02/11/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Expiration Date01/05/2023
Device Model Number105-0024
Device Catalogue Number104-0806
Device Lot NumberL2800
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 06/01/2022
Initial Report FDA Received Date03/25/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization;
Patient SexUnknown
-
-