Model Number 105-0024
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 02/17/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
This mdr has already been submitted to fda by the us importer with report number (b)(4).
 
Event or Problem Description
The patient was revised on (b)(6) 2022 due to state patient.Approximately 7 months after the first surgery.The surgeon explanted 1 glenoid baseplate (24), 1 centered glenosphere (36), 1 humeris stem (13), 1 humeral cup (36/3), 2 standard screws (40, 15) and 2 locking screws (20).The surgeon implanted 1 offset head (54x21) and 1 centered spacer (5).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HUMERIS REVERSED
Common Device Name
REVERSED SHOULDER PROSTHESIS
Manufacturer (Section D)
FX SOLUTIONS
1663 rue des majornas
viriat, 01440
FR  01440
Manufacturer (Section G)
FX SOLUTIONS
1663 rue des majornas
viriat, 01440
FR   01440
Manufacturer Contact
ratsamy thevenin
1663 rue des majornas
viriat, 01440
FR   01440
MDR Report Key13900965
Report Number3009532798-2022-00057
Device Sequence Number4391509
Product Code PHX
UDI-Device Identifier03701037300237
UDI-Public03701037300237
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K150488
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 02/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Expiration Date01/03/2026
Device Model Number105-0024
Device Catalogue Number105-0024
Device Lot NumberP1312
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/21/2022
Initial Report FDA Received Date03/25/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization;
Patient SexUnknown
-
-