Model Number APOLLO RF® H50, ASPIRATING, ABLATOR, 50°
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/11/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
During returned device evaluation, a reportable malfunction was discovered.Complaint confirmed.Visual evaluation reveals that the ceramic encasing the probe tip was chipped off, almost all around.The distal end of the shaft, near the ceramic is discolored.The electrodes is slightly darkened.The probe memory was checked and found to be free of error codes.The activation time record was 145s and connection time of 3015s.Device functioning was not performed, due to the damaged of the device.The cause of this event is undetermined; however, most likely causes are by prying/leveraging of the device against bone/bony tissue, device making contact with other devices, and use of the device for extended periods of time.
 
Event or Problem Description
It was reported that during a hip arthroscopy the device had a loose contact.No part of the device broke off.According to the surgeon no harm for patient, operator or third party occurred.The surgery was finished successfully with a new device with the same part number.It was not necessary to switch the surgical technique or do a second surgery.During returned device evaluation, a reportable malfunction was discovered.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
APOLLO RF® H50, ASPIRATING, ABLATOR, 50°
Common Device Name
ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
vik bajnath
8009337001
MDR Report Key13927693
Report Number1220246-2022-04642
Device Sequence Number14936415
Product Code GEI
UDI-Device Identifier00888867320253
UDI-Public00888867320253
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K161581
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 03/28/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/28/2026
Device Model NumberAPOLLO RF® H50, ASPIRATING, ABLATOR, 50°
Device Catalogue NumberAR-9835
Device Lot Number2011024
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/09/2022
Initial Report FDA Received Date03/28/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured03/01/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-